Installation and
Operation
Wiring Diagram
2
Description
Installation Instructions
The MultiSet/Multiset Pro Channel Remote is a designer-style, full-function, multi-location remote device that uses
existing three-way wiring to control MultiSet/MultiSet Pro dimmers or switches.
Channel Remotes use standard 3-way wiring. (see wiring diagram for details)
Note 1: If replacing an existing device with this device begin with Step #1 of Installation section.
Note 2: If installing this device in new construction begin with Step #4 of Installation section.
Reminder: Disconnect power at panelboard.
1. Remove faceplate from existing device.
2. Unscrew and pull device out of wallbox.
3. Disconnect wires from device. Using a wire box tester, identify and mark the “Hot” and the “Traveler” wires
connected to device.
4. Install device per the following notes;
IMPORTANT!
4a. Be sure Multiset Ground wire (bare stranded) is connected to earth ground.
Note: Miswiring, or failure to connect ground, may result in improper operation of device.
4b. If using Compli faceplate (sold separately): Before connecting any wires, be sure the Compli faceplate
mounting frame is behind the device with alignment tabs facing forward. Tabs should rest within centering
holes of Remote’s aluminum mounting strap.
5. After all connections have been made (see wiring diagram and notes!) be certain all wire connectors
are firmly attached.
6. Gently place wires
and backbox into wallbox (with LED at top of device) and screw in place.
7. Before installing faceplate, restore power to circuit.
8. After testing device for proper operation, install faceplate onto the device.
Features
• Streamlined appearance and operations
• A red LED light - to help locate the device in a dark room
• As an individual device, the MultiSet/MultiSet Pro Channel Remote has the capability to recall two presets - a
user-selected “on” level and full brightness.
• When used with a MultiSet/MultiSet Pro Scene Master, the remote has additional applications - on/off,
raise/lower and three way of a specific dimmer.
Caution
Caution: Be sure that power to the circuit being controlled has been disconnected by removing fuse or turning
circuit breaker off. Installing device with power on may expose you to dangerous voltage and damage the device.
Master MS-5
120VAC
LN
120VAC
L N G
MS
MS MS R
ON
A
B
C D
OFF
To Load
To Load
To Load
LN
120VAC
NL
120VAC
Operating Instructions
TURN LIGHTS ON TO PRESET
• Tap rocker top once. (A)
TURN LIGHTS FULL-ON
• Tap rocker top twice. (A)
ADJUST LIGHT LEVEL
• Press and hold down rocker top or bottom
until desired level is reached. (A or B)
• Release rocker
TURN LIGHTS OFF
• Tap rocker bottom once or twice. (B)
• Lights Fade off.
Note: When properly installed, the Red LED on the remote will be constantly
lit at half brilliance.
Fig. A
LED Indicator: (Fig. A)
Glowing RED = Power On (C)
Wiring Notes
Multiset Remote to Wallbox Wire
Black Hot (120V. Source, Must be same phase as dimmer)
Yellow Traveler Wire from MultiSet/MultiSet Pro Dimmer On switch
Bare Copper Earth Ground
*Grey Ground or Neutral
* For Remote LED operation connect grey to neutral or ground
Note 1: MSCR/MHCR can control one MultiSet/MultiSet Pro Dimmer or switch from one or multiple locations.
Note 2: MSCR/MHCR must be wired on the same circuit as the device it is controlling.
Note 3: MSCR/MHCR provides manual override for any one device (channel) of a MultiSet/MultiSet Pro system
Note 4: Each circuit feeding dimmers and dimmed loads requires a separate neutral. Shared neutrals will result in
undesirable flashing of controlled loads
Note 5: Line voltage must not be supplied by a GFI Breaker
MULTISET/MULTISET PRO - MSCR/MHCR
Note: No common neutrals on dimmed circuits.