How to Use the External Control
7 About the External Control
The Monitor has the MAKE/TRIGGER terminal, which allows you to control the monitor by the MAKE (make
contact) or TRIG. (trigger) system selected in the function setting.
MAKE (make contact) system: Controls the function by short-circuiting the corresponding pin terminal to the
GND pin terminal, or disconnecting (opening) it.
TRIG. (trigger) system: Controls the function by inputting the pulse signal instantaneously to the
corresponding pin terminal.
* Select “MAKE” or “TRIG.” from “REMOTE SYSTEM” in SET-UP MENU.
☞ “REMOTE SYSTEM” on page 12
NOTES:
• The external control has priority over operations using front panel buttons or menu functions of the monitor.
• When using the make contact system, you cannot use the functions which are applied to the MAKE/TRIGGER terminal
operating the front panel buttons or the menu of the monitor. (When using the trigger system you can also use those
functions operating the monitor directly.)
7 How to Use the MAKE/TRIGGER Terminal
7 Function of the MAKE/TRIGGER terminal
The following are the configurations and the functions
of the pin terminals of the RJ-45 connector. You can
change the functions applied to the 1st to 6th pin
terminals by setting “REMOTE SYSTEM” of SET-UP
MENU.
Caution:
This is a female
connector.
7 To change the functions applied to the pin
terminals
1. Display SET-UP MENU, then move the MENU/
VOLUME control to / to select “REMOTE
SYSTEM,” then move it to .
2. Move the MENU/VOLUME control to / to select
“CONTROL FORM,” then move it to / to select
“SET.”
3. Move the MENU/VOLUME control to / to select
the number of the pin terminal (PORT F1 – PORT
F6) you want to set, then move it to / to select
the function.
NOTE:
•You cannot apply two or more functions to one terminal.
NO.
1
2
3
4
5
6
7
8
INP. A
INP. B
CO. OFF
ASPECT
TALLY
STATUS
Functions to be controlled
Changes the input to INPUT A
Changes the input to INPUT B
Tur ns on/off COLOR OFF
Changes ASPECT
Controls the tally lamp
Tur ns on/off the status display
External control
GND
En_11-20_TM-1011G.p65 06.2.14, 22:3714