70
Applications
Unit Setting (continued)
Main Menu List (continued)
Item Preset Values Description
Reference
Page
C Error Report
Enables you to select how you want to be notified when an error is
detected in the system.
^
Dialog ⅷ Select check box
Do not select
check box
Select [Dialog] to display a warning dialog on the screen.
A
Page 151
Mail ⅷ Select check box
Do not select
check box
Select [Mail] to receive an e-mail notification on any abnormality at
the preset e-mail address.
Memo :
●
For details on errors, refer to the actions to take when the
[WARNING] indicator lights up. (
A
Page 151)
^
D Record Control
^
ON at startup ⅷ Select check box
Do not select
check box
Select this check box to turn on the recording control mode when
the system starts up.
E Mail Server
^
Enables you to configure the necessary information on the mail
server to be used if you have selected
A
Mail
B
in the [Error Report]
item
C
.
^
SMTP Server
Setting for the outgoing mail server.
Port Number ⅷ 25
User ID
^
Password
^
POP Server
Setting for the incoming mail server.
Port Number ⅷ 110
User ID
^
Password
^
SMTP
Authentication
ⅷ NONE
Authentication
POP before SMTP
Enables you to select the method of user authentication when
sending out a mail. For queries on the settings, consult your system
administrator.
Send Test Mail
Click to send out a test mail to the address specified in the [Mail
Send List] item
I
.
F Emergency Record
A
Page 52
Time of Record NONE
30seconds
ⅷ 60seconds
5minutes
10minutes
20minutes
Continue
Select the duration of emergency recording, which starts recording
of all channels when a signal is input to the [EMERGENCY]
terminal on the rear panel.
Select
A
Continue
B
to continue recording until it is stopped manually
on the front panel.