1-28 (No.YA139)
VIDEO - 2 SET: COMPONENT
4.7.7 VSM PRESET SETTING
Item
Measuring
instrument
Test point Adjustment part Description
H. POSITION
adjustment
Signal
generator
Remote
control unit
[4. DEF]
4. H-CENT
(1) Receive a PAL circle pattern signal to VIDEO-2
component terminal.
(2) Select VIDEO-2 SET from the MENU and set
VIDEO-2 SET to COMPONENT.
(3) Select 4. DEF from the SERVICE MENU.
(4) Select 4. H-CENT.
(5) Set the initial setting value of 4. H-CENT.
(6) Adjust 4. H-CENT to make "C=D".
(7) Press the [DISPLAY] key twice to return to the
normal screen.
Item
Measuring
instrument
Test point Adjustment part Description
VSM
PRESET
setting
Remote
control unit
[5. VSM W/B]
1. BRIGHT
2. CONT
3.COLOUR
4. SHARP
5. HUE
1. R-DRIVE
2. G-DRIVE
3. B-DRIVE
(1) Select 5. VSM W/B from the SERVICE MENU.
(2) Select BRIGHT with the MENU [OK] key.
(3) Set the value of 1. BRIGHT ~ 5. HUE to the values
shown in the table.
(4) Respectively select the VSM PRESET mode for
SOFT and STANDARD.
(5) Select COOL with the MENU [OK] key.
(6) Set the values of 1. R-DRIVE ~ 3. B-DRIVE to the
value shown in the table.
(7) Select the W/B preset for WARM and NORMAL,
respectively.
(8) Press the [DISPLAY] key twice to return to the
normal screen.
CD
VSM preset
BRIGHT STANDARD SOFT
Setting item
1. BRIGHT 0+2
2. CONT +15 -3
3. COLOUR 00
4. SHARP 00
0
0
0
0
-10
5. HUE 00
COOL
1. R-DRIVE 0
2. G-DRIVE 0
3. B-DRIVE 0
WARM
+10
-4
-12
NORMAL
+2
0
-10
[Setting Values for SUB 5. VSM W/B]
W/B preset
Setting item
SUB MENU 5. VSM W/B
1. BRIGHT
***
VSM PRESET BRIGHT