HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide 49
The following example configures SNMP trap 1:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> set setup snmp trap 1
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Current Values:
Trap1Enabled False
Trap1Address 10.0.0.254
Trap1Port 162
Trap1Severity warning
Trap1Version 2
Trap1Community public
New Value (press ENTER to not specify value, 'q' to quit):
Trap1Enabled (True / False) :True
Trap1Address (hostname, IPv4, or IPv6 Address) :10.20.30.40
Trap1Port (decimal value, 1-65535) :
Trap1Severity (select a severity level)
1=unknown 6=warning
2=emergency 7=notify
3=alert 8=info
4=critical 9=debug
5=error 10=mark :4
Trap1Version (1 / 2) :1
Trap1Community (string, max=32 chars) :OSEMcommunity
Do you want to save and activate this snmp setup? (y/n): [n]
For more information about CLI commands, see the HP StorageWorks SN6000 Fibre Channel Switch
Command Line Interface Guide.
4. Configure the switches in OSEM by adding each SN6000 Fibre Channel Switch as a Managed System
configured with System Type set to FC Switch and the IP address for the switch. For detailed instructions,
see the OSEM documentation available at the websites listed in ”Installation instructions and
documentation for SIM, RSP, OSEM, and ISEE” on page 47.