Maintenance and Troubleshooting
80 ESL E-Series Tape Library User’s Guide
Operating problems
Table 11 describes the corrective action for problems that occur during library
operation.
Table 11: Problems during library operation
Problem Corrective Action
The host computer
cannot communicate
with the library.
Verify that the host computer has been added to the
secure manager via the Command View ESL
software, and has been given access to library
components.
Verify cable connections and termination.
Verify that the FC port link LEDs show good status.
Restart the host and the library.
If the host and library still are not communicating,
verify that there is not a zoning issue.
A tape cartridge
(medium) is reported
not present.
This indicates that the picker could not sense a tape
cartridge in a particular storage bin, even though the
inventory reports that it is present.
Verify that the designated cartridge is present and
properly seated. (For a tape drive, make sure the
cartridge is completely unloaded.) Then, retry the
command.
Perform an inventory.
If the error persists, contact a field service engineer.