169
Software Fixes in Release M.08.51 - M.10.72
Release M.10.30
■ Transceiver hotswap (PR_1000390888) — Transceiver hotswap issues:
• Simultaneous hotswap of transceivers on both dual-personality ports will only detect a
single change.
• After certain transceiver hotswaps, the in/out LED indicator will not match the current
status of the transceiver.
• Unsupported mIni-GBIC's hotswapped out of dual personality ports will leave the
transceiver in an unknown state of partially inserted.
■ Transceiver hotswap (PR_1000294081) — The hotswap of a J4858A or B revision wire
release style mini-GBIC will result in the switch indicating a port fault condition for that port.
■ Web UI (PR_1000326265) — Attempting to access the Web UI of a stack member hangs
the browser.
Release M.10.30
Problems Resolved in Release M.10.30
■ Daylight savings (PR_1000364740) — Due to the passage of the Energy Policy Act of
2005, Pub. L. no. 109-58, 119 Stat 594 (2005), starting in March 2007 daylight time in the United
States will begin on the second Sunday in March and end on the first Sunday in November.
■ CLI (PR_1000395256) — The "loop-protect PORT-LIST receiver-action
<action>" command does not enable the ports as it should.
Release M.10.31
Problems Resolved in Release M.10.31
■ CLI (PR_1000240838) — If an invalid time is entered using "clock set" command, the
switch responds with an "invalid date" error.
■ CLI (PR_1000199785) — The tab help function (command-completion) for "IP RIP authen-
tication" is inaccurate. The help selection lists "OCTET-STR Set authentication key" when it
should be "ASCII-STR Set RIP auhentication key (maximum 16 characters)."
■ Crash (PR_1000398315) — Under certain conditions when Web Auth is in use, the switch
may crash with a message similar to:
PPC Bus Error exception vector 0x300:
Stack-frame=0x017b0dd0 HW Addr=0x8200a225 IP=0x00508ce4
Task='tHttpd' Task ID=0x17b0fa8