pRodUCt SpECifiCationS
pRodUCt SpECifiCationS
12 www.goodmanmfg.com SS-GPH13MC
SS-GPH13MC www.goodmanmfg.com 13
aiRflow data
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
GPH13
36M43*
Low 230
CFM 1122 1078 1032 972 915 804 687 558
Was 338 330 321 310 300 283 264 250
Med 230
CFM 1387 1331 1264 1209 1119 1041 935 748
Was 456 440 428 412 399 382 363 330
High 230
CFM 1521 1454 1388 1311 1230 1144 1055 939
Was 534 521 510 490 477 461 442 420
GPH13
48M43*
T1 (G) 230
CFM 1,440 1,395 1,360 1,310 1,265 1,235 1,190 1,130
Was 275 285 295 315 325 335 345 355
T2 / T3
(W2)
230
CFM 1,795 1,765 1,715 1,695 1,650 1,600 1,500 1,375
Was 475 490 505 520 530 535 510 475
T4 / T5 (Y) 230
CFM 1,860 1,820 1,785 1,745 1,700 1,625 1,515 1,395
Was 515 530 545 565 570 550 535 485
GPH13
60M43*
T1 (G) 230
CFM 1,755 1,720 1,685 1,645 1,615 1,570 1,530 1,465
Was 420 435 455 460 475 490 500 500
T2 / T3
(W2)
230
CFM 1,850 1,820 1,775 1,735 1,705 1,675 1,610 1,495
Was 480 500 515 525 535 555 545 520
T4 / T5 (Y) 230
CFM 2,180 2,125 2,050 1,975 1,875 1,800 1,655 1,530
Was 770 755 725 700 675 640 575 540
• Data shown is dry coil. Wet coil pressure drop is approximately 0.1" H₂O, for two-row indoor coil; 0.2” H₂O, for three-row indoor coil; and 0.3” H₂O, for four-
row indoor coil.
• Data shown does not include lter pressure drop, approx. 0.08” H2O.
• ALL MODELS SHOULD RUN NO LESS THAN 350 CFM/TON. USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM. See Repair Parts list.
• Reduce airow by 2% for 208-volt operaon.