TX200 S6 Operating Manual 47
Hardware installation
4.2 Setting up the floorstand model
I If you are not installing a PRIMERGY TX200 S6 floorstand model, skip
this section and continue reading at section "Installing/removing the rack
model" on page 49.
V CAUTION!
Follow the safety instructions in chapter "Important information" on
page 31.
Ê Transport the server to the place where you want to set it up.
Ê Unpack the server (see section "Unpacking the server" on page 46).
Ê Set up the server.
Note that for safety reasons (danger of tipping) the anti-tilt bracket must be
mounted on the back of the server (see section "Mounting the anti-tilt
bracket" on page 48).
V CAUTION!
The device must be protected from direct sunlight.
The essential minimum clearance for servicing must be
maintained (see "Maintenance area for the floorstand model" on
page 27).
Access to the rear of the server must be assured so that other
devices (e.g. memory subsystems) can be connected.
A clearance of at least 200 mm must be maintained in front of and
behind the system to ensure proper ventilation.
The mains plug must be accessible easily and safely.
Ê Wire the server. Read the information in section "Connecting devices to the
server" on page 59 and section "Notes on connecting/disconnecting cables"
on page 63.
Ê Connect the system to the mains (see section "Connecting the server to the
mains" on page 60).