CMM-17 Quick Start V1.2 03/05
9
Rotary Switch
Set the slide switch to the M or M/S position. Turn the meter ON and select the combined
function you desire by turning the rotary switch.
Figure-7 Rotary Switch for selecting combined function
FUNC.
INPUT (White color) OUTPUT (Yellow Color)
1 Power Off
Square wave output
Constant current: ± 25 mA
2
DC, AC or DC+AC Voltage
measurements.
Constant voltage: ± 1.5V, ± 15V
3 DC, AC or DC+AC mV measurements.
Constant voltage: ± 1.5V, ± 15V
4 Resistance/ Continuity measurements
Constant voltage: ± 1.5V, ± 15V
5 Diode/ Audible Continuity.
Constant current: ± 25 mA
Constant voltage: ± 1.5V, ± 15V
Constant current: ± 25 mA
6
DC, AC or DC+AC mA measurements:
50mA and 500 mA
Square wave output
Output and Input Terminals
Figure-8 Output/Input Terminals
1
2
6
5
OUTPUT terminals for Constant
Voltage, Constant Current and
Square wave Output functions
INPUT terminals for Voltage,
Current, Resistance, Diode/ Audible
Continuity measurements