6.25 Terminate Remote Mode “ ESC 00H 00H 00H ”
Format:
ESC 00H 00H 00H
Function:
- The following procedures are executed:
- The default environment is copied to the current environment.
- If interface related items have been changed, the interface related state and
settings are changed.
- Software initialization is executed (If in ESC/P mode, initialization by ESC @.
In other printer languages, initialization corresponding to ESC @.)
- The remote mode is terminated, and the mode is changed to the selected
printer language.
- This command is only valid in remote mode.