![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/e/6c/e6c80413-b27c-4630-b19d-b047cc856ab4/e6c80413-b27c-4630-b19d-b047cc856ab4-bg656.png)
1622 System Management Commands
Unit NSF Support
---- -----------
1 Yes
2 Yes
3 Yes
Per Unit Status Parameters are explained as follows:
Example – Switch Firmware Stack Status
The following example displays the Switch Firmware stack status information
for the switch.
console#show switch
Management Standby Preconfig Plugged-in Switch Code
SW Switch Status Model ID Model ID Status Version
--- ---------- --------- ------------- ------------- ------------- ---------
1 Mgmt Sw ANFirebolt-48 ANFirebolt-48 OK 4.12.17.37
2 Stack Mbr ANFirebolt-24 ANFirebolt-24 Updating Code 13.4.8.42
console#show switch 1
Switch............................ 1
Management Status................. Management Switch
Hardware Management Preference.... Unassigned
Admin Management Preference....... Unassigned
Switch Type....................... 0xb6340001
Preconfigured Model Identifier.... PCT7048
Plugged-in Model Identifier....... PCT7048
Switch Status..................... OK
Switch Description................ PowerConnect 7048
Expected Code Type................ 0x100b000
Detected Code Version............. 5.31.1.46
Parameter Description Range Default
NSF Support Whether a unit
supports NSF
Yes or No —
2CSPC4.XCT-SWUM2XX1.book Page 1622 Monday, October 3, 2011 11:05 AM