![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/12/c1211803-deb5-448e-852b-9ca2202116a4/c1211803-deb5-448e-852b-9ca2202116a4-bgf.png)
Instructions to Configure BFi for Intel NIC 15
To configure the iscsibcg.exe utility to run every time the system is turned off,
perform the following steps:
a
Click
Start
→
Ru
n.
b
Ty p e
gpedit.msc
and click
OK
.
c
In the
Group Policy
window, expand
Computer Configuration
→
Windows Settings
→
Scripts (Startup/Shutdown)
.
d
In the
Scripts (Startup/Shutdown)
screen, double-click
Shutdown
.
e
In the
Shutdown Properties
screen, click
Add
.
f
Locate the
iscsibcg.exe utility
(default location is
c:\Windows\System 32\
)
in the
Script Name f
ield and type
/verify /fix
in the
Script
Parameters
field.
g
Click
OK
.
Configuring the PowerVault MD3000i Storage Array
1
Perform the following procedure to manually register a host:
a
Open the P
owerVault Modular Disk Storage Manager
, and connect to
the PowerVault MD3000i storage array to be used by the host for
booting.
b
Select the
Configure
tab, and then click
Configure Host Access
(Manual)
.
c
In the
host
field, enter the host name, select the
host type
from the
drop down list, and then click
Next
.
d
In the
Selected iSCSI initiators
field, click the
New
button.
e
In the
iSCSI initiator name
field, enter the
iSCSI Qualified Name
(IQN) of the host initiator and leave the iSCSI Initiator label to the
default.
Fully qualified IQN format is
<iqn><yyyy-mm>.com<company
name>:<server name>
.
Example:
iqn.1984-04.com.dell:server-name
. Record the
IQN of the host initiator in the "Configuration Worksheet" on
page 77. The IQN of the host initiator is required to configure Intel
iSCSI boot BIOS.
f
Click
Add
and then click
Next
.