Table A-14 shows the wattage output possible with the 4200W power supply in
redundant mode. In redundant mode, both power supplies must have identical
inputs and all inputs must be at the same voltage. If the input voltages are
mismatched, choose the value matching the weaker of the two power supplies.
Table A-15 shows the wattage output possible with the 4200W power supply in
conbined mode.
Table A-14 Redundant Mode Output
12V 3.3V -50V Total
110 660 40 700 1050
110+110 or 220 1360 40 1850 2100
220+220 1360 40 3700 4200
Table A-15 Combined Mode Output
12V 3.3V -50V Total
Both sides at 110 1200 40 1200 1873
110+110, other side 110 1360 40 2000 2728
220+220 1360 40 3100 3782
Both sides at 110+110 1360 40 3100 3782
Both sides at 220 1360 40 4700 5493
Both sides at 220+220 1360 40 6800 7600