![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/54/954a9bac-de6b-40fb-9d05-6b0cf6e1e494/954a9bac-de6b-40fb-9d05-6b0cf6e1e494-bg45.png)
6-9
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
OL-10853-01
Chapter 6 Hardware Diagnostic Tests
Displaying Hardware Errors
You can also view POST error codes with the show diagnostic post command. This command displays
the results of each POST that executes at power-up.
SFS-7000P# show diagnostic post
======================================================================
Post Status
======================================================================
fru-slot post-status error-codes
--------------------------------------------------------------------------------
card(1) failed 1:0:0:0
fan(1) passed 0:0:0:0
fan(2) passed 0:0:0:0
power-supply(1) passed 0:0:0:0
Step 2 Display FRU errors on your switch by entering the show diagnostic fru-error command.
SFS-7000P# show diagnostic fru-error
======================================================================
Fru-Error
======================================================================
fru-slot fru-error
--------------------------------------------------------------------------------
card(1) _FRU_POWER_CONTROLLER_CONFIG_ERR
fan(1) none
fan(2) none
power-supply(1) none
Table 6-1 lists the hardware errors that are logged for the power supply.
Table 6-1 Cisco SFS 7000P and SFS 7000D Server Switches Power Supply Errors
Error Number Description
1 Power supply DC fail error
2 Power supply fan fail error
3 Power supply I2C communication error