6-4
Cisco ONS 15200 Product Description
78-13766-01
Chapter 6 Engineering Specifications
Optical
Figure 6-1 15252 MCU optical path
6.2.3.2 Single-Channel Unit Optical Loss
Table 6-5 provides optical loss information for the SCU. See Figure 6-2 and Figure 6-3 to locate the
paths where loss occurs in the SCU (for example, from I to H in a Collector Filter Module [CFM]).
Figure 6-2 shows an unprotected path, and Figure 6-3 shows a protected path in the SCU.
Insertion loss, MU-type 0.3 —
Insertion loss, SC-type 0.3 —
Table 6-4 MCU Optical Loss (continued)
Equipment Maximum (dB)
Includes
connectors
(Y/N)
61890
LM A
NAM 1
Filterbank A
X
10% input/output
monitor A
HPO
V
V
HFM 1A HFM 2A
CLIP 1
LM B
NAM 2
Filterbank B
Y
10% input/output
monitor B
IMN
BK
R
HFM 2BHFM 1B
CLIP 2
Table 6-5 SCU Optical Loss
Equipment Maximum (dB)
Includes
connectors
(Y/N)
Collector Filter Module: Unprotected (100/0 or 0/100)
Through loss (adjacent channel), I to H 0.9 Y
Through loss (non-adjacent channel), I to H 0.8 Y
Drop loss, I to K 2.1 Y
100% Add loss, B to H 1.9 Y
Collector Filter Module: Protected (90/10 or 10/90)
Through loss (adjacent channel), I to H 1.4 Y