![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/c5/9c5d5b57-c14d-4e32-80b4-e4df40ba59cd/9c5d5b57-c14d-4e32-80b4-e4df40ba59cd-bg2e.png)
5. USING THE OPERATION PANEL (BASIC OPERATIONS)
KE-430FX/KE-430FS, BE-438FX
37
4
Select the item to be changed.
Press the SELECT key.
・ The selected parameter changes in the order shown in
the illustration below each time the SELECT key is
pressed.
Pattern Æ X-scale Æ Y-scale Æ Sewing speed Æ Slow start patternÆ Upper thread tension
5
Change the setting for the parameter.
(Refer to “List of parameters” on the next page for details
on parameter changes. )
Press the
or key to change the parameter
setting.
・ The flashing display means that the parameter setting
has not yet been applied.
・ You can make the initial setting appear in the display
by pressing the RESET key.
6
Apply the changed parameter setting.
Press the ENTER key.
・ The display will change from flashing to illuminated,
and this means that the setting has been applied.
・ If you press the SELECT key or the TEST key without
pressing the ENTER key, you can cancel the
parameter changes.
7
Repeat steps 4 to 6 above to record the settings for each parameter.
8
If you would like to continue setting another program, repeat steps 2 to 7 above.
9
Exit program mode.
TEST indicator switches off
Press the TEST key.
・The display will return to the normal display.
2401B
2402B
2403B
2404B
2382B 2383B