3. READING / WRITING DATA
25
BAS-311G, BAS-326G
3-4. Data read/write mode
1
With the power turned off, insert the CF card into the CF
slot.
NOTE:
• Make sure the CF card is facing the correct way.
• Always be sure to keep the cover closed except
when inserting and removing the CF card. If this is
not done, dust may get inside and cause problems
with operation.
• If no valid data can be found, the CF media indicator
will not illuminate.
2
Turn on the power switch.
3
Switch to data read/write mode.
TEST indicator and CF media indicator illuminate
While pressing the TEST key, press the R/W key.
• The mode number will appear in the PROGRAM No.
display, and the setting details for that mode will
appear in the menu display.
• The initial mode is sewing data reading mode. (Refer
to the read/write mode list)
4
Press the or key to select the mode.
[Read/write mode list]
PROGRAM No.
display
Menu display Setting items
r 1 [-SEd] Sewing data is read from the CF card. (*1)
w 2 [SEd-] Sewing data is written to the CF card.
r 3 [-MEM] Memory switch settings are read from the CF card.
w 4 [MEM-] Memory switch settings are written to the CF card.
r 5 [-UPG] User programs are read from the CF card.
w 6 [UPG-] User programs are written to the CF card.
r 7 [-SyS] Control programs are read from the CF card and used to update the firmware version.
w 8 [LoG-] Error log data is written to the CF card.
r 9 [-Fdd] Sewing data is read from the floppy disk. (*2) (*3)
w 10 [Fdd-] Sewing data is written to the floppy disk. (*2)
r 11 [-EoP] Extended option output (*4) data is read from the CF card.
w 12 [EoP-] Extended option output data is written to the CF card.
r 13 [oPFd] Extended option output data is read from the floppy disk. (*2)
*1 The sewing data that can be use with this sewing machine is data that has been created for the BAS-311G/BAS-326G.
*2 Only valid when using an optional floppy disk drive.
*3 Sewing data for the BAS-300 series, BAS-300A series and BAS-300E/F series can be read.
*4 Refer to the instruction manual for the programmer for details on extended option output.