98 en | Advanced configuration Divar 700 Series
F.01U.246.471 | v3.6 | 2011.11 Installation and Operation manual Bosch Security Systems
Figure 6.26 Configuration menu - Storage - Disks - All
All disks
All available disks are shown in the list.
– Select Internal disks to see a list of installed internal disks and their capacity in
gigabytes.
– iSCSI disk locations are also shown. Locations can be added or removed from the list by
clicking Add location or Remove location.
– When Add location is selected, a pop-up window appears; fill in the IP address and
port of the iSCSI array to be added.
– Select an individual hard disk from the list and click Properties to view the status of the
selected disk.
6.10.3 Service
– Delete recording until... - opens a submenu to delete video older than a specified date.
– Delete all recordings - will erase all video on all hard disks in the active disk set
(protected drives will also be erased).
– Pause recording... - pauses all recordings for a specified period of time.
6.10.4 Replacing a disk
Power down the recorder and replace the faulty drive with a spare one and reboot.
The Disk set tab still shows 4 disks in the active disk set. In the Disks / In use tab the faulty
drive is listed together with the 3 good drives. In the Disks / All tab the 3 good drives with the
replacement drive are shown.
1. Remove the faulty drive from the active disk set in the Disks / In use tab.