4 — MAINTENANCE
3. Once the battery voltage reaches a predetermined level programmed in the
electronic control, the yellow “80% CHARGE” LED will illuminate.
4. The charge will be completed 3-1/2 hours after the yellow “80% CHARGE”
LED is lit. The charger and all LED’s will automatically shut off. The battery
charge level indicator should indicate at least 3/4 charge.
NOTE: If the battery voltage does not reach the 80% level within 14 hours, the
charger will shut off and the “CHECK BATTERY” LED will light up.
CAUTION
Before making or breaking connections between charger and battery, always
remove the power cord from the 115 volt outlet. For more information, refer to
the instructions supplied with the battery charger.
5. After the charge cycle is completed, disconnect the battery charger cord from
the wall outlet, place it back into its box, and close and latch the lid. LIFT
WILL NOT OPERATE IF THE LID IS NOT CLOSED SECURELY.
4-6 LIFT CHAINS AND SLIDE BLOCKS
WARNING
Do not operate a unit on which any chain assembly is damaged or in need of re-
placement. Operating a unit with a damaged chain can cause severe injury or
death to personnel and damage to equipment.
Inspect all lift chains every 6 months. Inspect for signs of wear, split leaves, loose pins,
clevis damage, and elongation. Replace any chain that is damaged in any way. Chain as-
semblies may be ordered from your dealer or direct from the factory. Do not operate a
unit on which any chain assembly is damaged and in need of replacement.
Chain Elongation Inspection
Refer to Figure 4-11. Measure 20 pitches of chain. Twenty pitches of new chain should
measure 12.5 in. (31.75 cm). Replace the chain if a 20-pitch length measures over 12.75
in. (32.385 cm).
Figure 4-11. Chain Elongation Inspection
4-13