ZyXEL Communications 3110 Garage Door Opener User Manual


 
Chapter 4 SHD2110/3110 Programming
Z-Wave Series Programming Guide
18
4.2.1.4 Meter Report Command
The SHD2110/3110 will report its instant power consumption to Grouping 1. For detailed
description of meter report command, refer to page 4.
4.2.2 Grouping 2
Grouping 2 includes the BASIC_SET commands. To control associated Z-Wave devices, the
BASIC_SET command must be enabled. After receiving commands from the Z-Wave Controller,
the SHD2110/3110 controls the on/off status of all devices associated in grouping 2. If you press
the On/Off button on the SHD2110/3110, all devices associated will be turned on or off
simultaneously.
4.2.2.1 Control Other Z-Wave Devices (Basic Set)
This enables or disables the BASIC_SET command. Refer to the Z-Wave’s Configuration section to
configuration parameter 1 for the setting of basic set command.
Note: The SHD2110/3110 can associate with up to 4 SHD2110/3110s, acting as an active
and passive device respectively. The active device cannot be set and controlled by
passive one.
4.2.3 Z-Wave’s Configuration
The table below lists the configuration parameters and the value range for users to set up the
SHD2110/3110.
4.2.3.1 The True Period
If the True Period set to 10 seconds, pressing the On/Off button alternately within 10 seconds will
not send out RF command. After 10 seconds, the SHD2110/3110 will examine if current On/Off
state is the same as before. If it’s the same, no RF command will be sent, whereas if it is different,
RF command will be sent to update the status. The maximum interval is 12 second
(100ms*12=12000ms).
4.2.3.2 Send Basic Command to Grouping 2
If the Send Basic Command is set to 0, the SHD2110/3110 will not send out commands to other
devices of Grouping 2 for On/Off operation if you press the On/Off button manually. If the setting is
configured for 1, the SHD2110/3110 will send out commands to other devices of Grouping 2 for On/
Off operation.
Table 2 Z-Wave Configuration Table
PARAMETER FUNCTION SIZE (BYTE) VALUE UNIT
FACTORY
DEFAULT
DESCRIPTION
1 True Period 1 0~120 100ms 10 10x100ms=1 second
0: Disable
2 Send Basic
Command to
Group 2
1 0.1 0 0:Disable
1:Enable
3 (SHD3110
only)
Meter Report
Period
2 0-3240
(9 Hours)
10s 3 3x10=30 seconds
0:Disable