York YCSA Heat Pump User Manual


 
45
Elektrische installatie
YCSA/YCSA-H 50 en 60 T en TP
NL
L1
PE
L3
N
L2
VOEDINGSSPANNING
400V - 3 + N - ph - 50Hz
C
CO
C
NO
NC
AAN/UIT SCHAKELAAR OP AFSTAND
POMPRELAIS MAX. 10 VA 230 V
(ALLEEN UITVOERING ZONDER PACK)
3
7
24
VCA (UITGANG)
AANSLUITKLEMMEN CONTACTSTRIP YCSA/YCSA-H
AANSLUITKLEMMEN EXTERNE TOESTELLEN
CONTACT ZONDER SPANNING
CONTACTSTRIP YCSA/YCSA-H
ELEKTRISCHE INSTALLATIE KLANT
PLAAT AANSLUITKLEMMEN
YCSA/YCSA-H
EXTERNE PLAAT AANSLUITKLEMMEN
HOOFDSCHAKELAAR
AANSLUITKLEM ZONDER SPANNING
PRINTPLAAT A1
4
5
6
ALGEMEEN ALARM (OMKEERCONTACT ZONDER
SPANNING MAX. 10 A WEERSTAND A 250 Vca)
1
7
I
DEBIETREGELAAR (BIJ UNITS ZONDER PACK EEN CONTACT
NO VAN DE CONTACTSCHAKELAAR VAN DE POMP EN EEN
CONTACT NO VAN DE THERMOMAGNETISCHE SCHAKELAAR
VAN DE POMP IN SERIE MET DE DEBIETSCHAKELAAR TOEVOEGEN).
2
7
SCHAKELAAR KOELING/VERWARMING
OP AFSTAND. GESLOTEN = VERWARMING,
OPEN = KOELING (ALLEEN YCSA-H)
8