York TCGF24 THRU 60 Air Conditioner User Manual


 
413434-LTG-E-0909
6 Johnson Controls Unitary Products
— = Not applicable.
TCGF30S41S1
AHP36 21 1000 29.6 21.4 14.30 12.20
AHX30 17 1025 29.6 22.0 15.25 13.00
AHX36 21 1005 30.2 22.6 16.25 13.00
AHX42 21 990 30.6 22.8 16.50 13.25
AHX48 24 1090 31.0 23.6 16.50 13.25
F6FP030 17 1035 29.2 21.8 15.00 12.75
F6FP036 21 980 29.2 21.6 15.25 13.00
F6FP042 21 1065 30.8 23.4 16.50 13.25
F6FP048 24 1055 28.2 21.6 16.25 13.00
TCGF36S41S1
AHP36 21 1200 35.4 26.2 15.00 12.50
AHX36 21 1225 35.2 26.0 15.50 12.75
AHX42 21 1190 35.6 26.2 15.75 13.00
AHX48 24 1255 35.8 26.8 15.75 13.00
AHX60 24 1300 36.0 27.2 15.75 13.00
F4FP036 21 1200 34.2 25.2 14.00 12.00
F4FP040 21 1200 34.4 25.0 14.00 12.00
F4FP042 21 1200 34.4 25.0 14.00 12.00
F5FP048 24 1250 36.4 27.4 16.25 13.50
F5FP060 24 1250 34.8 26.0 15.25 13.00
F6FP036 21 1210 34.0 24.8 15.50 12.75
F6FP042 21 1290 35.6 27.0 15.75 13.00
F6FP048 24 1125 33.4 24.0 15.75 13.00
F6FP060 24 1240 35.8 26.6 15.75 13.00
TCGF42S41S1
AHX42 21 1395 42.0 31.6 15.00 12.50
AHX48 24 1445 42.0 32.2 15.25 12.75
AHX60 24 1440 42.0 32.2 15.25 12.75
F5FP048 24 1450 42.0 32.0 15.50 13.00
F5FP060 24 1500 40.0 29.8 14.75 12.50
F6FP042 21 1455 42.0 32.0 15.00 12.50
F6FP048 24 1380 39.5 29.6 15.25 12.75
F6FP060 24 1475 42.5 32.4 15.25 12.75
TCGF48S41S1
AHP/SHP60 24 1600 44.0 30.6 14.20 12.00
AHX48 24 1660 47.5 34.4 14.75 12.50
AHX60 24 1680 48.0 34.4 15.00 12.50
F5FP048 24 1700 47.5 34.0 15.00 12.75
F5FP060 24 1700 44.5 31.2 14.00 12.00
F6FP048 24 1625 44.5 31.2 14.75 12.50
F6FP060 24 1710 48.0 34.8 15.00 12.50
TCGF60S41S1
AHX60 24 1570 55.5 37.2 14.50 12.50
F6FP060 24 1710 56.5 39.0 14.25 12.25
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.