413434-LTG-E-0909
6 Johnson Controls Unitary Products
— = Not applicable.
TCGF30S41S1
AHP36 21 – 1000 29.6 21.4 14.30 12.20
AHX30 17 – 1025 29.6 22.0 15.25 13.00
AHX36 21 – 1005 30.2 22.6 16.25 13.00
AHX42 21 – 990 30.6 22.8 16.50 13.25
AHX48 24 – 1090 31.0 23.6 16.50 13.25
F6FP030 17 – 1035 29.2 21.8 15.00 12.75
F6FP036 21 – 980 29.2 21.6 15.25 13.00
F6FP042 21 – 1065 30.8 23.4 16.50 13.25
F6FP048 24 – 1055 28.2 21.6 16.25 13.00
TCGF36S41S1
AHP36 21 – 1200 35.4 26.2 15.00 12.50
AHX36 21 – 1225 35.2 26.0 15.50 12.75
AHX42 21 – 1190 35.6 26.2 15.75 13.00
AHX48 24 – 1255 35.8 26.8 15.75 13.00
AHX60 24 – 1300 36.0 27.2 15.75 13.00
F4FP036 21 – 1200 34.2 25.2 14.00 12.00
F4FP040 21 – 1200 34.4 25.0 14.00 12.00
F4FP042 21 – 1200 34.4 25.0 14.00 12.00
F5FP048 24 – 1250 36.4 27.4 16.25 13.50
F5FP060 24 – 1250 34.8 26.0 15.25 13.00
F6FP036 21 – 1210 34.0 24.8 15.50 12.75
F6FP042 21 – 1290 35.6 27.0 15.75 13.00
F6FP048 24 – 1125 33.4 24.0 15.75 13.00
F6FP060 24 – 1240 35.8 26.6 15.75 13.00
TCGF42S41S1
AHX42 21 – 1395 42.0 31.6 15.00 12.50
AHX48 24 – 1445 42.0 32.2 15.25 12.75
AHX60 24 – 1440 42.0 32.2 15.25 12.75
F5FP048 24 – 1450 42.0 32.0 15.50 13.00
F5FP060 24 – 1500 40.0 29.8 14.75 12.50
F6FP042 21 – 1455 42.0 32.0 15.00 12.50
F6FP048 24 – 1380 39.5 29.6 15.25 12.75
F6FP060 24 – 1475 42.5 32.4 15.25 12.75
TCGF48S41S1
AHP/SHP60 24 – 1600 44.0 30.6 14.20 12.00
AHX48 24 – 1660 47.5 34.4 14.75 12.50
AHX60 24 – 1680 48.0 34.4 15.00 12.50
F5FP048 24 – 1700 47.5 34.0 15.00 12.75
F5FP060 24 – 1700 44.5 31.2 14.00 12.00
F6FP048 24 – 1625 44.5 31.2 14.75 12.50
F6FP060 24 – 1710 48.0 34.8 15.00 12.50
TCGF60S41S1
AHX60 24 – 1570 55.5 37.2 14.50 12.50
F6FP060 24 – 1710 56.5 39.0 14.25 12.25
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.