York TCGD12 THRU 60 Air Conditioner User Manual


 
400034-YTG-B-0708
Johnson Controls Unitary Products 3
Additional R-22 Charge / Orifice Size for Various Matched Systems
Outdoor Unit
TCGD12
S21S2(H)
TCGD18
S21S2(H)
TCGD24
S21S2(H)
TCGD30
S21S2(H)
TCGD36
S21S2(H)
TCGD42
S21S2(H)
TCGD48
S21S2(H)
TCGD60
S21S2
Required Orifice or TXV
1,2
0.041 / 2A 0.052 / 2A 0.059 / 0.061 / 2A 0.065 / 2A 0.073 / 2A 0.081 / 2C 0.084 / 2C 0.096 / 2C
Factory R-22 Charge, lbs-oz 3 - 2 3 - 0 3 - 13 3 - 7 3 - 15 4 - 2 4 - 5 5 - 4
Indoor Coil
3,4
Additional Charge, Oz
FC/MC/PC/UC18A2A 0 0 –––––
FC/MC/PC/UC18B2A 0 0 –––––
FC/MC/PC/UC24A2A –0 –––––
FC/MC/PC/UC24B2A –0 –––––
FC/MC/PC32A2A –– +3 +4 ––––
FC/MC/PC35B2A –– +3 +4 ––––
FC/MC/PC35C2A –– +3 +4 ––––
FC/MC/PC/UC36A2A –– 0 –––––
FC/MC/PC/UC36B2A –– 0 –––––
FC/MC/PC/UC36C2A –– 0 –––––
FC/MC/PC37A2A – +7 +12 +4
FC/MC/PC43B2C –– ––0 ––
FC/MC/PC43C2C –– ––0 ––
FC/MC/PC/UC48C2C – +5 +2
FC/MC/PC/UC48D2C – +5 +2
FC/MC62D2C –– ––––0
HC18A2A 0 0 –––––
HC30A2A –– 0 –––––
HC36B2A –– +3 +4 ––––
HC42C2C – +12 +4 0
AHP18B2A 0 0 –––––
AHP24B2A –0 –––––
AHP30B2A –– +3 +4 ––––
AHP36C2A – +12 +4
AHP42C2C –– ––0 ––
AHP/SHP60D2C –– –––0
AV24B2A –+2 –––––
AV36C2A – +7 +12 +4
AV/SV48D2C –– –––0
FC/MC/PC/UC18A3X 41 + 0 52 + 0 –––––
FC/MC/PC/UC18B3X 41 + 0 52 + 0 –––––
FC/MC/PC/UC24A3X 52 + 2 –––––
FC/MC/PC/UC24B3X 52 + 2 –––––
FC/MC/PC32A3X –– 61 + 3 65 + 4 ––––
FC/MC/PC35B3X –– 61 + 3 65 + 4 ––––
FC/MC/PC35C3X –– 61 + 3 65 + 4 ––––
FC/MC/PC/UC36A3X –– 59 + 0 –––––
FC/MC/PC/UC36B3X –– 59 + 0 –––––
FC/MC/PC/UC36C3X –– 59 + 0 –––––
FC/MC/PC37A3X 61 + 7 65 + 12 73 + 4
FC/MC/PC43B3X 61 + 7 65 + 12 73 + 4 81 + 0
FC/MC/PC43C3X 61 + 7 65 + 12 73 + 4 81 + 0
FC/MC/PC/UC48C3X 73 + 4 81 + 5 84 + 2
FC/MC/PC/UC48D3X 73 + 4 81 + 5 84 + 2
FC/MC62D3X –– ––––96 + 0
HC18A3X 41 + 0 52 + 0 –––––
HC30A3X –– 59 + 0 –––––
HC36B3X –– 61 + 365 + 4 ––––
HC42C3X 61 + 7 65 + 12 73 + 4 81 + 0
For Notes See Page 4.