York AHP18 Air Conditioner User Manual


 
255029-YTG-M-0610
Johnson Controls Unitary Products 5
All air handler units are UL Listed up to 0.50" w.c. external static pressure, including air filter, wet coil, and largest KW size heater, unless otherwise
noted.
AIR FLOW DATA - 60 Hz MODELS
Models
Blower
Motor
Speed
230 Volt
CFM
1
@ External Static Pressure - IWC
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
AHP18B**H21
High 1054 989 923 862 791
665 581 202 N/A N/A
Medium 782 762 716 670 613
536 315 121 N/A N/A
Low 541 519 479 445 397
298 168 N/A N/A N/A
AHP24B**H21
High 1232 1167 1098 1025 940
826 731 622 486 345
Medium 966 915 868 799 724
641 540 452 347 224
Low 785 740 684 618 532
446 364 296 192 131
AHP30B**H21
High 1434 1359 1297 1220 1138
1050 916 782 640 519
Medium 1112 1076 1031 970 907
802 629 507 394 380
Low 885 854 821 751 686
625 547 459 350 N/A
AHP36C**H21
High 1760 1681 1607 1538 1456
1360 1322 1260 966 770
Medium 1320 1284 1255 1207 1146
1075 988 846 729 572
Low 1146 1119 1090 1038 992
972 841 725 617 496
AHP42C**H21
High 1883 1764 1657 1543 1435
1327 1210 902 714 527
Medium 1625 1510 1429 1339 1256
1172 1038 765 609 412
Low 1260 1225 1179 1110 1047
973 785 638 500 340
AHP48D**H21
High 2029 1944 1837 1743 1643
1537 1435 1320 1064 789
Medium 1805 1730 1649 1566 1479
1385 1286 1147 851 683
Low 1491 1441 1388 1328 1253
1174 1076 867 726 555
AHP60D**H21
High / #1 2256 2226 2198 2159 2095
1959 1914 1776 1519 1380
Medium High / #2 1990 1963 1935 1893 1857
1820 1783 1698 1486 1353
Medium / #3 1774 1748 1704 1670 1635
1593 1534 1480 1384 1325
Medium Low / #4 1557 1523 1483 1432 1389
1329 1265 1235 1198 1167
Low / #5 1340 1300 1253 1198 1126
1079 1037 1007 954 912
1. Includes return air filter and coil.
APPLICATION FACTORS - RATED CFM VS. ACTUAL CFM
% Of Rated Airflow
80% 90% Rated CFM 110% 120%
Capacity Factor
0.96 0.98 1.00 1.02 1.03