ALL SENSIBLE CAPACITIES
TABLE 3: COOLING CAPACITIES - 1-1/2 TON (DEB018)
TEMPERATURE
OF AIR ON
OUTDOOR COIL
AIR ON INDOOR COIL
450 CFM 525 CFM 600 CFM 675 CFM 750 CFM
WB °F WB °F WB °F WB °F WB °F
72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57
85 °F
Net Cap
MBH
18.1 17.3 16.0 16.3 18.2 17.4 16.1 16.4 18.4 17.5 16.2 16.5 19.0 18.2 16.8 17.1 19.7 18.8 17.4 17.7
Total Power
Input kW
1.77 1.75 1.74 1.72 1.82 1.81 1.79 1.78 1.87 1.86 1.85 1.83 1.91 1.90 1.88 1.87 1.95 1.94 1.92 1.91
Sensible Capacity
MBH
1
1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity
Entering Dry
Bulb °F
86 10.1 13.1 15.9 16.3 10.8 14.0 16.1 16.4 11.5 14.8 16.2 16.5 12.3 15.7 16.8 17.1 13.1 16.7 17.4 17.7
83 8.8 11.8 14.7 16.0 9.3 12.4 15.4 16.3 9.8 13.0 16.0
16.5 10.3 13.7 16.7 17.1 10.9 14.4 17.4 17.7
80 7.5 10.6 13.4 14.7 7.8 10.9 13.8 15.2 8.0 11.3 14.3 15.7 8.3 11.7 14.9 16.3 8.7 12.2 15.5 17.0
77 6.2 9.3 12.1 13.4 6.2 9.4 12.3 13.7 6.3 9.5 12.5 14.0 6.3 9.8 12.9 14.4 6.4 10.0 13.2 14.8
74 4.9 8.0 10.8 12.1 4.7 7.9 10.8 12.2 4.5 7.8 10.8 12.2 4.4 7.8 10.9 12.4 4.2 7.7 11.0 12.5
71 - 6.7 9.5 10.9 - 6.4 9.3 10.7 - 6.0 9.0 10.5 - 5.8 8.9 10.4 - 5.5 8.8 10.3
68 - 5.4 8.2 9.6 - 4.9 7.8 9.1 - 4.3 7.3 8.7 - 3.8 6.9 8.4 - 3.3 6.5 8.1
95 °F
Net Cap
MBH
16.2 16.1 13.7 14.1 17.0 16.8 14.3 14.8 17.8 17.6 15.0 15.5 18.0 17.8 15.1 15.6 18.1 17.9 15.3 15.8
Total Power
Input kW
1.88 1.89 1.84 1.84 1.94 1.95 1.90 1.89 1.99 2.00 1.95 1.95 2.02 2.03 1.98 1.97 2.04 2.05 2.00 2.00
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 9.1 12.6 13.7 14.1 10.2 14.1 14.3 14.8 11.3 15.5 15.0 15.5 11.9 16.2 15.1 15.6 12.5 16.8 15.3 15.8
83 7.9 11.4 13.2 13.6 8.7 12.6 14.1 14.6 9.6 13.8
15.0 15.5 9.9 14.2 15.1 15.6 10.3 14.6 15.3 15.8
80 6.6 10.1 11.9 12.3 7.2 11.0 13.1 13.5 7.8 12.0 14.3 14.7 7.9 12.2 14.4 14.9 8.1 12.3 14.6 15.1
77 5.3 8.8 10.7 11.1 5.7 9.5 11.6 12.0 6.1 10.3 12.5 13.0 6.0 10.2 12.5 12.9 5.8 10.1 12.4 12.9
74 4.0 7.5 9.4 9.8 4.2 8.0 10.1 10.5 4.3 8.5 10.8 11.2 4.0 8.2 10.5 10.9 3.6 7.9 10.2 10.7
71 - 6.2 8.1 8.5 - 6.5 8.6 9.0 - 6.8 9.0 9.5 - 6.2 8.5 9.0 - 5.6 7.9 8.4
68 - 4.9 6.8 7.2 - 5.0 7.0 7.5 - 5.0 7.3 7.7 - 4.2 6.5 7.0 - 3.4 5.7 6.2
105 °F
Net Cap
MBH
15.2 14.6 12.7 13.2 15.9 15.2 13.3 13.8 16.6 15.9 13.9 14.3 16.9 16.2 14.1 14.6 17.2 16.5 14.4 14.9
Total Power
Input kW
1.99 2.00 1.96 1.94 2.05 2.06 2.02 2.00 2.11 2.12 2.08 2.06 2.14 2.15 2.10 2.09 2.16 2.17 2.13 2.11
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 8.7 12.0 12.7 13.2 9.8 13.4 13.3 13.8 10.9 14.8 13.9 14.3 11.6 15.4 14.1 14.6 12.3 15.9 14.4 14.9
83 7.4 10.7 12.4 12.6 8.3 11.9 13.1 13.5 9.2 13.2
13.9 14.3 9.6 13.7 14.1 14.6 10.1 14.2 14.4 14.9
80 6.2 9.4 11.1 11.3 6.8 10.4 12.2 12.5 7.4 11.4 13.4 13.6 7.6 11.7 13.7 14.0 7.8 12.0 14.1 14.4
77 4.9 8.1 9.8 10.0 5.3 8.9 10.7 10.9 5.7 9.7 11.6 11.9 5.6 9.7 11.7 12.0 5.6 9.8 11.8 12.1
74 3.6 6.9 8.5 8.7 3.8 7.4 9.2 9.4 3.9 7.9 9.9 10.1 3.7 7.7 9.8 10.0 3.4 7.5 9.6 9.9
71 - 5.6 7.2 7.4 - 5.9 7.7 7.9 - 6.2 8.1 8.4 - 5.7 7.8 8.0 - 5.3 7.4 7.6
68 - 4.3 5.9 6.2 - 4.3 6.2 6.4 - 4.4 6.4 6.6 - 3.7 5.8 6.0 - 3.1 5.1 5.4
115 °F
Net Cap
MBH
14.3 13.1 11.8 12.2 14.8 13.6 12.3 12.7 15.4 14.2 12.8 13.2 15.9 14.6 13.2 13.6 16.3 15.0 13.5 14.0
Total Power
Input kW
2.10 2.11 2.07 2.04 2.17 2.17 2.14 2.11 2.23 2.24 2.21 2.18 2.26 2.27 2.23 2.20 2.28 2.29 2.26 2.22
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 8.3 11.3 11.8 12.2 9.4 12.8 12.3 12.7 10.5 14.2 12.8 13.2 11.3 14.6 13.2 13.6 12.1 15.0 13.5 14.0
83 7.0 10.1 11.5 11.5 7.9 11.3 12.1 12.4 8.8 12.5
12.8 13.2 9.3 13.2 13.2 13.6 9.8 13.9 13.5 14.0
80 5.7 8.8 10.2 10.2 6.4 9.8 11.4 11.4 7.0 10.8 12.5 12.6 7.3 11.2 13.0 13.1 7.6 11.7
13.5 13.6
77 4.4 7.5 8.9 8.9 4.9 8.3 9.9 9.9 5.3 9.0 10.8 10.8 5.3 9.2 11.0 11.1 5.4 9.4 11.3 11.3
74 3.2 6.2 7.6 7.7 3.3 6.8 8.3 8.4 3.5 7.3 9.0 9.1 3.3 7.2 9.0 9.1 3.1 7.2 9.1 9.1
71 - 4.9 6.4 6.4 - 5.2 6.8 6.8 - 5.5 7.3 7.3 - 5.3 7.1 7.1 - 5.0 6.8 6.9
68 - 3.6 5.1 5.1 - 3.7 5.3 5.3 - 3.8 5.5 5.6 - 3.3 5.1 5.1 - 2.7 4.6 4.6
125 °F
Net Cap
MBH
13.3 11.6 10.9 11.3 13.7 12.0 11.3 11.7 14.2 12.4 11.7 12.1 14.8 13.0 12.2 12.6 15.4 13.5 12.7 13.1
Total Power
Input kW
2.2 2.2 2.2 2.1 2.3 2.3 2.3 2.2 2.4 2.4 2.3 2.3 2.4 2.4 2.4 2.3 2.4 2.4 2.4 2.3
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 7.9 10.7 10.9 11.3 9.0 12.1 11.3 11.7 10.1 13.5 11.7 12.1 11.0 13.8 12.2 12.6 11.9 14.1 12.7 13.1
83 6.6 9.4 10.6 10.4 7.5 10.7 11.1 11.3 8.4 11.9
11.7 12.1 9.0 12.7 12.2 12.6 9.6 13.6 12.7 13.1
80 5.3 8.1 9.3 9.2 6.0 9.2 10.5 10.3 6.6 10.2
11.7 11.5 7.0 10.8 12.3 12.1 7.4 11.3 13.0 12.8
77 4.0 6.9 8.1 7.9 4.5 7.6 9.0 8.8 4.9 8.4 9.9 9.7 5.0 8.8 10.3 10.1 5.2 9.1 10.7 10.6
74 2.7 5.6 6.8 6.6 2.9 6.1 7.5 7.3 3.1 6.7 8.2 8.0 3.0 6.8 8.3 8.2 2.9 6.9 8.5 8.3
71 - 4.3 5.5 5.3 - 4.6 6.0 5.8 - 4.9 6.4 6.2 - 4.8 6.3 6.2 - 4.6 6.3 6.1
68 - 3.0 4.2 4.0 - 3.1 4.4 4.2 - 3.2 4.7 4.5 - 2.8 4.4 4.2 - 2.4 4.0 3.9