‘Wolflite’ Primary Cell Safety Handlamp H-4DC
Operation and Maintenance Instructions
Certification
EEx e ib IIB T4 Certificate: BASEEFA Ex. 843292 Certificate: 86/00089
Use of ‘Wolflite’ Primary Cell Handlamps in Hazardous Areas
The H-4DC Handlamp is approved for use in potentially explosive gases and vapours
zone 1 and 2. Applicable standards: EN 50014:1977, EN 50019:1977, EN 50020:1977.
Copies of Certificates are available on request.
Users should consult EN IEC 60079 for guidance on the selection, use, inspection
and maintenance of products for use in potentially explosive atmospheres, or
national equivalent.
A damaged Lamp should be withdrawn, examined and repaired before being put back
into service.
Maintenance and repair must only be carried out by a competent technician or electrician
familiar with Certified Electrical Apparatus, in accordance with these maintenance
instructions using factory supplied spare parts.
Lamps must not be opened in hazardous areas. All maintenance to be carried out in
a safe area.
Ingress Protection Level for H-4DC Handlamp: IP 66 to EN 60529:1992.
Heavily soiled Lamps must not be immersed in water or exposed to high pressure water
jets for cleaning.
The H-4DC Handlamp body may constitute a static hazard, clean only with a damp cloth.
Permissible Hazardous Area ambient temperature: –20°C to +50°C.
Primary cell powered lamps are supplied without cells.
Primary Cells
Use only D size R20 zinc cells, to IEC 60086.
DO NOT MIX CELLS; DO NOT USE RECHARGEABLE CELLS