Wolf H-251 Indoor Furnishings User Manual


 
‘Wolflite’ H-251 Rechargeable Safety Handlamp Range
Operation & Maintenance Instructions
Certification
EEx e s II T3 Certificate: BASEEFA Ex 81142 Certificate: 86/00097
Use of Wolflite Handlamps in Hazardous Areas
The H-251 Mk1/Mk2 Handlamps are certified for use in potentially explosive gases and vapours.
Applicable standards: EN50014:1977, EN50019:1977, SFA 3009:1972.
Ingress protection level for H-251 Mk1: IP66, to EN60529:1992 for H-251 Mk2: IP54 to EN60529:1992.
Users are advised to consult EN IEC 60079 for guidance on the selection, use, inspection and
maintenance of products for use in potentially explosive atmospheres, or national equivalent.
The lamp must not be opened or fitted with replacement parts in a hazardous area. Lamp chargers must
be kept and operated in non hazardous areas and in clean and dry conditions; a damaged lamp should
be carefully examined for its continued safety. If in doubt, it should be withdrawn from use and returned
to the manufacturer for repair.
The ‘Wolflite’ Handlamp may constitute a static hazard and should be cleaned only with a damp cloth.
Heavily soiled lamps must not be immersed in water or exposed to high pressure water jets for cleaning.
Maintenance and repair must be carried out by a competent technician/electrician familiar with Certified
Electrical Apparatus and in accordance with these maintenance instructions, using factory supplied
spare parts only.
Handlamp operating ambient in Hazardous Areas: -20°C to +40°C
Before Use
Charge battery before first use. To prevent accidental discharge of the battery in transit, the switch is
locked in the OFF position.
To Lock/Unlock the Lamp
The stainless steel lock screw in front of the handle interlocks with the operating switch. Screw anti-clockwise
to lock the lamp enclosure and release the operating switch. The lock key provided must be kept in a
non-hazardous area.
WARNING: The Lock Screw bush can be dislodged if overtightened. Switch ‘OFF’ before
screwing the Lock Screw down.
To Operate and Dismantle the Switch
The switch operates transversely, as indicated on the approval label. It consists of a magnet, a plastic
housing and a cap. To replace, the old cap is prised off and the housing removed. The new switch
housing/magnet is fitted to the body before the cap is ‘snapped’ in place.
To Open the Lamp
Unlock as above, unscrew the lens ring from the body to gain access to all internal parts.
To Replace the Bulb
The bulb (3.6 Volts, 1.0 Amp) is retained by the screwed centre contact at the back of the reflector.
8842 H-251E H-251 mk1&2 30/6/06 12:02 Page 4