GROUNDING INSTRUCTIONS
D-250 98828 04/25/02
3
THIS PRODUCT IS FOR COMMERCIAL USE ONLY.
ELECTRICAL:
The amp, hertz, and voltage are listed on the
data label found on each machine. Using
voltages above or below those indicated on the
data label will cause serious damage to the
motors.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should
malfunction or break down, grounding provides a
path of least resistance for electric current to
reduce the risk of electric shock. This appliance
is equipped with a cord having an equipment-
grounding conductor and grounding plug. The
plug must be inserted into an appropriate outlet
that is properly installed and grounded in
accordance with all local codes and ordinances.
The D250 is for use on a nominal 115-volt circuit,
and has a grounded plug that looks like the plug
in “Fig. A”. A temporary adaptor that looks like
the adaptor in “Fig . C” may be used to connect
this plug to a 2-pole receptacle as shown in “Fig.
B”, if a properly grounded outlet is not available.
The temporary adaptor should be used only until
a properly grounded outlet (Fig. A) can be
installed by a qualified electrician. The green
colored rigid ear, lug, or the like extending from
the adaptor must be connected to a permanent
ground such as a properly grounded outlet box
cover. Whenever the adaptor is used, it must be
held in place by a metal screw.
The D250IE is for use on a nominal 230-volt
circuit.
Improper
connection of the
equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified
electrician or service person if you are in doubt as
to whether the outlet is properly grounded. Do
not modify the plug provided with the appliance -
if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
Warning:
Using the incompatible chemicals listed above
will damage the machine. Damages of this
type are not covered under the 6-3-1 warranty.
Carefully read ingredients on manufacturer's
label before using any product in this machine.
WARNING:
NOTE: In Canada, the use of a temporary adaptor is no
t
p
ermitted by the Canadian Electrical Cod
e
PROPER GROUNDING (115V)
Metal Screw
Adaptor
Grounded Outlet Box
Fig. A
Fig. B
Fig. C
Tab For Grounding Screw
Grounded
Outlet
Grounding Pin
Adaptor
CHEMICALS
Suitable Chemicals
A
lkalis
Detergents
Hydroxides
Soaps
Vinegar
Non-Compatible
A
ldehydes
A
romatics Hydrocarbons
SP Butyls
Carbon Tetrachloride
Clorox*
Chlorinated Bleaches
Chlorinated Hydrocarbons
Lysol*
Methyl Ethel Ketone (MEK)
Perchorethylene (perc)
Phenolics
Trichlorethylene
D-Limonene