TROUBLESHOOTING CONT.
D-250 98637 06/19/00
9
Solution hose Corrosion on fittings Clean with steel wool.
fitting hard to Soak in acetic acid (white vinegar).
connect Lubricate lightly with silicone base
lubricant.
Carpet not Severe soil conditions Make several passes at right angles to
getting clean. other. Use a prespray.
Carpet too wet Over saturation Adjust solution pressure to lower setting.
Make several passes without spray.
Carpet browning Leaving carpet too wet Check for loss of vac pressure.
Too much chemical in Check label for correct solution
concentration. .
Solution not Solution hose connection Check for positive connection
flowing properly
Faulty pump Repair or replace.
Faulty floor tool valve Repair or replace.
Faulty pump switch Repair.
TECHNICAL SPECIFICATIONS
POWER TYPE
ELECTRICAL: 115 V, 60 Hz, 15 Amps per power cable ((D250)
230 V, 50 Hz, 15 Amps (D250IE)
ELECTRIC VACUUM MOTOR: (1) –2/1.25 HP, 2 stage, Waterlift –150” (381cm)
SOLUTION PUMP: 250 psi, adj.
SOLUTION CAPACITY: 17 gallons (64.3ltr)
RECOVERY CAPACITY: 15 gallons (56.75ltr)
GENERAL DIMENSIONS/WEIGHT
WEIGHT: 97 lbs. ( 44 kg)
LENGTH: 20” (50.80 cm)
HEIGHT: 36” (91.44 cm)
WIDTH: 16” (40.64 cm)
POWER CABLE: 2-25’ (6.35 m) (D250)
1-25' (6.35 m) (D250IE)