Windsor CS24 10060210 Vacuum Cleaner User Manual


 
SCRUB CONTROLS-BASIC-CYLINDRICAL
86037660 CHARIOT 11/09/06
3-10
1. SQUEEGEE LIFT LEVER
Raises and lowers the squeegee, and turns the vacuum motor on and off.
To lower squeegee and start vacuum motor, lift the lever from its raised position.
To raise squeegee and stop vacuum motor, lift the lever from its lowered position.
2. ACTUATOR SWITCH
Raises and lowers the scrub deck, turns the scrub brush motors on and off, and adjusts the amount of
brush/pad pressure to the floor.
To lower the scrub deck, turn on scrub brush motors, and/or increase brush pressure, press the bottom of
the switch.
To raise the scrub deck, turn off scrub brush motors, and/or decrease brush pressure, press the top of the
switch.
3. BRUSH PRESSURE INDICATOR
The brush pressure indicator corresponds to the amp draw of the scrub brush motors to tell how hard the
motors are working. The blue zone indicates medium or proper brush pressure. The red zone indicates
heavy or excessive brush pressure. Operating in the red zone may cause the brush circuit breakers to trip.
4. SOLUTION CONTROL KNOB
Controls solution flow to scrub deck
To increase flow, rotate knob clockwise.
To decrease flow, rotate knob counterclockwise.
If the brush motors are turned off or the throttle pedal is in neutral, the flow is automatically interrupted until
the motors are turned on again. This feature prevents unintentional draining of the solution tank and allows
the operator to adjust the solution flow to the scrub deck without resetting each time the scrubbing
operation is interrupted.