Windsor ADPJ Carpet Cleaner User Manual


 
POTENTIAL
INJURY:
Warning:
This product contains moving parts.
To reduce the risk of injury
-
unplug the
machine before servicing.
Maintenance and repairs must be done
by qualified personnel ONLY.
CAUTION:
Using non-Windsor parts to repair this
machine will void the 6-3-l warranty.
Suggested Service Parts List
DESCRIPTION
PART NUMBER
Belt 11015
Brush Bearinas
09019
115V
Cord Assemblv (USA/Japan) 23086
115V
Cord End
(USA)
26009
Dome Assemblv 28033
Dome Gasket 35060
Hose Cuff, Blue
27354
Hose Cuff, White
27079
Jet Assemblv 44055
Jet
44061
Jet Seal
44051
Jet Bodv w/Seal
44052
Manifold Assemblv 54095
Screen/Filter, Dome
34140
Screen/Filter. Solution Tank
73772
DAILY MAINTENANCE:
These procedures are followed at the end of each
work period to extend the life of the machine.
1.)
2.)
3.)
4.)
5.)
6.)
7.)
Empty unused cleaning solution by dis-
connecting clear hose on back of machine and
pouring into floor drain.
Inspect and clean solution filter screen inside
tank and vac intake screen inside dome.
Flush the system. Fill solution tank with 1 or
2 gallons (4
-
8 liters) of clean ot water. With
machine over floor drain turn on vac/pump
switch until solution tank is empty.
Inspect spray pattern of jets.
Remove jets and
rinse if clogged.
After each use, rinse tank with fresh water.
Periodically inspect the recovery tank and
decontaminate if necessary, using a Hospital
Grade Virucide or a l-1 0 bleach to water
solution. Waste water should be disposed of
properly.
Remove any lint or debris from brush.
Inspect power cord. Remember, this cord
will lay on damp carpet.
Warning:
IMMEDIATELY REPLACE
WORN OR FRAYED POWER CORDS.
8.)
Inspect hoses. Worn or cracked
hoses may cause loss of vac pressure.
9.)
Place the brush in the storage position. Press
back slightly on the main handle, press down
on the control knob and turn until the pin drops
into the slot; rotate another 90to lock.
For infrequent use or long periods of
storage,
flush the system with a neutralizing
solution of 1 quart (1 liter) white vinegar
mixed with 2 gallons (8 liters) hot water.
Flush the system with clean hot water after
neutralizing.
8
98198
7/l/97