Windsor 621-222MO Carpet Cleaner User Manual


 
MAINTENANCE
NINJA INTL 86038610 03/29/07
4-4
PRESSURE REGULATOR
For best results with the pressure regulator, we recommend that you clean and lubricate
the piston and u-cup with Superlube lubricant monthly or when pressure drop seems excessive.
1. Turn unit off before lubricating.
2. Remove cap, spring and spring retainer plate.
3. With fingertips remove piston and u-cup.
4. Wipe piston and u-cup clean of any film or scale.
5. Lubricate the piston and u-cup with Superlube.
6. Reassemble regulator.
7. With pump ON, re-adjust pressure regulator for normal operation.
LUBRICATE U-CUP WITH SUPERLUBE MONTHLY.
PISTON
OUT
IN
U-CUP
SPRING
CAP
SPRING RETAINER PLATE