Windsor 10086150 Vacuum Cleaner User Manual


 
MACHINE OPERATION
86292490 VOYAGER DUO 08/20/07
3-14
HOSE
SOLUTION
DRAIN
EMPTYING AND CLEANING SOLUTION TANK
1. Park the machine next to a floor drain. Drain
hose is at the rear of the machine.
2. Turn the machine power off.
3. Remove the top of the hose from the barb mount
and lower hose in direction of the drain. Do not
stand in front of end of hose. Solution will come
out with force.
4. Remove the front cover and solution fill cover.
5. Flush the solution tank out with clean water and
run several gallons of clean water through both
spray jet systems. Do not use water hotter than
140°F (60°C) to clean tank or damage may
occur.
6. Replace the drain hose to the barbed fitting.
7. If machine is to be stored, leave the solution fill
cover off.
EMPTYING AND CLEANING CHEMICAL TANKS
AND SYSTEM (DELUXE)
1. Turn the machine power off.
2. Park the machine next to a floor drain. The
tanks are located at the front of the machine.
3. Remove the cap and straw from each chemical
bottle and install the closed caps.
4. Remove the tanks by lifting off the solution fill
tower.
5. The chemical can remain in the tank or be
disposed of properly. Remove one cap at
a time and dispose of chemical. Rinse tanks
with clean water.
6. Rinse the chemical system by putting the straws
and caps in clean water. Push the prime/flush
switch for 30 seconds in each direction, “A” and
“B”.
EMPTYING AND CLEANING REOVERY TANK
1. Park the machine next to a floor drain. Drain
hose is at the front of the machine.
2. Turn the machine power off.
3. Remove front cover. Remove hose assembly
from mounting hook. Place the end of the hose
at the drain and slowly remove the cap. Do not
stand in front of hose end. Soiled solution will
come out with force.
4. Remove dome lid.
5. Flush the recovery tank out with clean water.
Do not use water hotter than 140°F (60°C) to
clean tank or damage may occur.
6. Replace the drain hose cap and place hose
back on hook. Replace front cover.
7. If machine is to be stored, leave the recovery
dome off.