Windsor 10070570 Vacuum Cleaner User Manual


 
MAINTENANCE
CMPS2 86305210 04/23/08
4-2
1. FLOAT SHUT-OFF
The float shut-off is located inside the
recovery tank. The purpose of the float
shut-off is to notify the user that the
recovery tank is full. Remove daily and
clean any debris for maximum airflow.
2. STRAINER
The strainer is located on the left side
between the front and rear wheels. The
strainer protects the pump from debris. If
there is little or no solution flow to the
ground, check the stainer for debris. Drain
the solution tank and clean the solution
strainer. To remove the strainer, turn the
bottom part of the strainer counterclockwise
until the bottom is separated. Clean out the
debris from the wire mesh and reassemble.
Make sure the o-ring gasket is in place
when reassembled.
3. CIRCUIT BREAKERS
Circuit breakers interrupt the flow of power
in the event of an electrical overload. When
a circuit breaker is tripped, reset it by
pressing the exposed button. If a circuit
breaker continues to trip, the cause of the
electrical overload should be found and
corrected.
PUMP MOTOR
10 AMP
VACUUM MOTOR
8 AMP
120V
230V
5 AMP
PUMP MOTOR
7 AMP
VACUUM MOTOR