MAINTENANCE
SCX364 86037150 03/14/07
4-5
FOR SAFETY: When charging, connect the
charger to the batteries before connecting the
charger to the AC wall outlet. Never connect the
charger to the AC wall outlet first. Hazardous
sparks may result.
7. Plug the charger connector into the battery
connector. Connect the charger AC plug to a
wall outlet. The charger gauge should indicate
that the batteries are charging.
8. When the batteries are fully charged, disconnect
the charger from the AC wall outlet, then
disconnect the charger from the batteries.
9. Connect the batteries to the machine connector.
10. Check the electrolyte level. It should be up to
the indicator ring. If necessary, add distilled
water.
11. Lower the battery cover.
1. Current level being delivered to the batteries
will be displayed on the charger’s bar graph.
2. When battery charge level has reached 80%
the YELLOW “80%” LED will light.
3. Batteries will then receive a low current
“finish-charge” indicated by the flashing
GREEN “100%” LED.
4. Charging cycle is complete when “100%”
LED is continuously GREEN.
5. Disconnect charger’s AC power cord.
6. Raise battery cover and check the battery
electrolyte level. It should be up to the
indicator ring. If necessary, add distilled
water.
7. Lower the battery cover.
CHANGING BATTERIES
Stop the machine in a clean area next to the
charger. Turn off machine.
FOR SAFETY: Before leaving or servicing the
machine; stop on level surface, turn off machine
and remove key.
1. Raise the battery cover.
2. Disconnect battery pack from machine.
3. Use the proper size open-end wrench to
disconnect main ground wire first and secure
cable terminal away from batteries.
4. Disconnect main positive lead and secure cable
terminals away from batteries.
5. Loosen both terminals on each jumper cable
and remove one at a time.
6. Prepare a suitable site to place the batteries.
7. Attach suitable battery lifting device and lift
batteries from the machine.
Batteries are a potential environmental hazard.
Consult your battery supplier for safe disposal
methods.
RED BLK
-
-
BLK
-
RED
REDRED
-
BLK
BLK
-
BLK
RED
RED
BLK
+
+
+
+
++
-
FRONT OF MACHINE