COMPONENTS/CONTROLS
86038450 04/12/07
3-1 EN
G
1. Hour Meter. Records machine use time.
2. Battery Condition Light. Indicates the charge condition of batteries.
3. Main Power Switch. Turns On and Off the machine.
4. Pad Pressure Meter. “Green Area” indicates correct pad pressure range.
5. Burnishing Head Switch. Raises and lowers burnishing head.
6. 3 Amp Circuit Breaker. Thermal circuit breaker protects lift mechanism. Press to reset.
7. Main Handle.
8. Handle Adjustment Lever.
9. Breaker. 60 amp magnetic circuit breaker, protects pad driver motor. Press to reset.
10. Pad Motor Switch Bar. Raising bar turns on pad driver motor.
11. Pad Adjustment Knob. Rotating knob adjusts pad pressure.
12. Reverse Button (Traction model only). Propel bar must be squeezed and button pushed for
reverse travel.
13. Speed Control (Traction model only). Knob rotated left to right for slow to fast speed.
14. 15 Amp Circuit Breaker (Traction model only). Protects transaxle.