White Rodgers ECS750W Air Cleaner User Manual


 
0508082120/101203/C Page 6 Owner’s manual
Operating Instructions
7 TROUBLESHOOTING
If leds • and •••• are flashing:
This is the Service Indicator. It signifies time to service (replace
or clean) the filter(s).
Pressing any button will turn off the Service Indicator leds.
When the unit is switched on again the Service Indicator will
resume flashing. After changing the filter(s), the Service
Indicator should be reset in Program Setting 2. Contact your
service person.
If led AUTO is flashing:
Air Quality Analyzer is warming up. After 5 minutes the Air
Quality Analyzer is ready and air cleaner will start running in
AUTO mode.
If led STANDBY is flashing:
High Voltage Output problem in the collecting cell(s).
If there is a dead short in the cell for over 60 seconds the
STANDBY led flashes. Power will be interrupted to the cell(s) for
10 minutes which may allow the cause of the problem (e.g.
hair) to flow out of the collecting cell. After 10 minutes the high
voltage will return to the cell. If there is still a short in the cell
the high voltage will again be interrupted for 10 minutes, etc.
This loop stops at the fourth time a dead short condition is
detected. Upon detection, the software blocks the fan control
and the unit quits operating. The collecting cell should be
cleaned to see if it can be returned to service or requires further
repair. Contact your service person.
Note: After one crackle or snap (arcing) the high voltage will
drop to 7000 Volts and slowly build up to the programmed
output. If there are more than 20 crackles or snaps during one
minute, the software blocks the high voltage for 45 seconds,
after which the voltage slowly rebuilds.