White Rodgers SST1000 Air Cleaner User Manual


 
7
Vertical
Section
Wood Block
Tape All
Joints
Figure 16
Hot
Neutral
Grounding
Conductor
Front View
Figure 17
Floor
Conduit
Duct
Electronic
Air Cleaner
Figure 18
Cabinet
Pre-Filters
Handle
Contact
Button
Contact
Button
Collecting Cells
Power Pack
Figure 19
7. With the cabinet installed, the air cleaner can now be
wired to electrical input source.
WARNING
!
Installation of this unit must comply with localInstallation of this unit must comply with local
Installation of this unit must comply with localInstallation of this unit must comply with local
Installation of this unit must comply with local
electric codes or other applicable codes.electric codes or other applicable codes.
electric codes or other applicable codes.electric codes or other applicable codes.
electric codes or other applicable codes.
Review and understand local codes prior to in-Review and understand local codes prior to in-
Review and understand local codes prior to in-Review and understand local codes prior to in-
Review and understand local codes prior to in-
stallation.stallation.
stallation.stallation.
stallation.
Failure to do so could result in serious personalFailure to do so could result in serious personal
Failure to do so could result in serious personalFailure to do so could result in serious personal
Failure to do so could result in serious personal
injury or death.injury or death.
injury or death.injury or death.
injury or death.
8. This air cleaner unit has no air flow monitor installed,
it does require electrical wiring through the furnace
controls. Connect wiring to the furnace control termi-
nals. (EAC-H) for power, (EAC-N) for neutral, and
connect metal frame of EAC to ground. If air flow
monitor is required for operation, order F859-0381 Air
Flow kit. Install kit and connect a 120 VAC 60 Hz input
circuit. A 20 amp circuit is more than adequate.
9. Remove junction box cover and install the required
bushing into the 3/4 in. Knock out. With the supply
voltage turned off, route three (3) wires into junction
box for connections. (See Fig. 17.)
Insure all wires are clamped, wire connectors prop-
erly installed and grommets used to prevent wire
abrasion.
WIRING INSTRUCTIONSWIRING INSTRUCTIONS
WIRING INSTRUCTIONSWIRING INSTRUCTIONS
WIRING INSTRUCTIONS
10. With the cabinet Installed, reinstall pre-filter(s) and
collecting cell(s) (Figure 19).
NOTE: The contact button and handles on the cell
must be facing you and ionizing wires must be on the
air intake side.
11. Install the power pack as follows:
Engage the lip on lower inside edge of power pack in
the flange on cabinet and carefully close the power
pack, making sure that the electrical connector prongs
on the power pack enter the slots in the socket on
cabinet. When the power pack is fully in place, en-
gage the latch and snap it closed.