White Rodgers 37-7248A Thermostat User Manual


 
4
INSTALLER/CONFIGURATION MENU
1 & 2)Keypad Lockout – This menu selection will display
Lk” and “OFF” (default, keypad not locked out). The
and are used to toggle the selection between
OFF and “L” (keypad locked out). When the keypad
lockout selection is enabled “L”, and the MENU button
is pressed again, the display will indicate the number
“0” (default, still disabled) in the time digits. The
and
are used to set the combination number from 0
to 999. If a combination of 0 is selected and the MENU
button is pressed, the menu will be exited and keypad
will not be locked. If 1 to 999 is selected and the MENU
button is pressed, the combination is stored into memory
and the menu is exited. The “Lk” will display designating
keypad locked with a valid combination. The SYSTEM
button will operate for 10 seconds after the menu mode
is exited to allow the user to change the mode from
OFF” to the desired SYSTEM mode.
While the keypad is locked out, a press of MENU will en-
ter the configuration menu. The first menu item displayed
is the combination code “0”. The
or keys are
used to set the combination unlock number from 0 to
999. If the unlock number matches exactly with the com-
bination lock number stored in memory when the MENU
button is pressed, the keypad is unlocked and the “Loc”
is removed. If the unlock number does not match when
the MENU button is pressed, the combination returns to
“0” for another attempt to set the unlock code. To exit the
menu without unlocking the keypad, press RUN SCHED.
To reset the combination code and unlock the keypad if
the code is forgotten, see troubleshooting section.
3) Select Reversing Valve Output (SS/HP switch must be set
at HP, omitted if SS/HP switch is SS Position) – The O/B
option is factory set at "O" position. This will accommodate
the majority of heat pump applications, which require the
changeover relay to be energized in COOL. If the thermo-
stat you are replacing or the heat pump being installed
with this thermostat requires a "B" terminal, to energize the
changeover relay in HEAT, the O/B option should be set at
"B" position.
To enter the Configuration Menu, SYSTEM must be set to HEAT, COOL, Em or AUTO. Press the Menu button for at least 5
seconds. The display will show item #1 in the table below. Press Menu button to advance to the next menu item. Press
or
to change an item option. Shaded items are not available on 1F86.
INSTALLER/CONFIGURATION MENU
Menu
Screen
Number
SS HP
Displayed
(Factory Default)
Press
or to
select from listed options
Comments
01
(OFF) Lk L Selects Keypad Lockout.
(Not available on earlier models)
02
(000) Lk 001 to 999 Selects Keypad lockout combination number
03
(Cool O) On Heat b On Reversing Valve Output (SS/HP switch must be in
the Heat Pump HP position)
04
(2) P P 3, P 0 Selectable Programs Per Week
(For programmable thermostat only)
05
(OFF)
Cool Savings CS
Cool Savings CS On Select Cool Savings On of OFF
06
(3) CS 6, 5, 4, 3, 2, 1 Selects Cool Savings value 1 (low) to 6 (high)
07
(On) E E OFF Selects Energy Management Recovery (EMR)
On or OFF
(For programmable thermostat only)
08
(ME)
CR Heat
SL, FA Adjustable Anticipation (Heat) (only when SS/HP
switch is at the SS position)
09
(FA)
CR Cool
SL Adjustable Anticipation (Cool) (only when SS/HP
switch is at the SS position)
10
(FA)
CR Heat Pump
SL Adjustable Anticipation (Heat Pump)
(only when SS/HP switch is at the HP position)
11
(OFF) CL CL On Compressor Lockout Time
12
Auto-Heat
Cool-Off
Heat-Cool-Off, Heat-Off
with Fan icon,
Heat-Off without Fan icon,
Cool-Off, Auto-Off
System Mode Configuration with Automatic
Changeover
13
(On) dL OFF Selects Display Light On or OFF
14
0 HI 1 HI, 2 HI, 3 HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
15
°F °C
Selects Fahrenheit/Celsius Temperature Display
16
L (90) Heat L 62 to L 89 Selects Limited HEAT Range
17
L (45) Cool L 46 to L 82 Selects Limited COOL Range
18
(OFF) Change Filter Change Filter On Selects Filter Change-out Indicator
19
(200 h) Change
Filter
25 h to 1975 h in
25-hour increment
When on, selects time in 25 hour increments
25-hour increment