White Rodgers 37-5234E Furnace User Manual


 
Printed in U.S.A.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Operator: Save these instructions for future use!
Ideal for use on wall heaters, space heaters, consoles,
etc., this gas pilot safety valve provides 100% shut-off of
both pilot and main burner gas supply in the event of pilot
flame failure. This valve is equipped with a 3-position gas
control knob to provide for pilot lighting. This control also
allows pilot flame adjustment.
If the pilot flame goes out during normal operation, or if
there is insufficient pilot flame to provide proper thermo-
couple output, the safety valve will close, stopping the
flow of all gas. This valve is designed for use on all
domestic heating gases up to
1
2” PSI.
764-700 to 764-759
Dual Inlet Gas Pilot Safety Valve
(Thermocouple-Operated)
R
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
INSTALLATION INSTRUCTIONS
WHITE-RODGERS
Thermocouple
connection
DUAL INLET
(NOTE: One inlet to be plugged)
Gas control
knob
Pilot adjust
cover screw
Outlet
Inlet
Pilot gas
tapping
Inlet
SPECIFICATIONS
Capacity (for AGA natural gas at 1” drop):
3
8” x
3
8” size:
side inlet – 112,000 BTU/hr.
bottom inlet – 107,000 BTU/hr.
1
2” x
1
2” size:
side inlet – 124,000 BTU/hr.
bottom inlet – 118,000 BTU/hr.
Pilot connection:
1
4” tubing
Pressure:
1
2” PSI maximum
Ambient Rating: -40°F to 250°F operating temperature
Mounting Position: Multipoise
Ignition Source: Pilot
Type of gas: Suitable for all domestic heating gases
Thermocouple: Use W.R. Type H06E
Accessories: Item Part No.
Replacement Knob F42-0895
Stem Extender F145-1111
Approvals: ANSI Z21.78 Combination Gas Control
CAN 1-6.4
CAN 1-9.1
PART NO. 37-5234E
Replaces 37-5234D
9502
DO NOT USE THESE GAS VALVES WITH
UNVENTED APPLICATIONS.
CAUTION
!