Operating Instructions
5 CONTROL
See fig. 5 on page 25
Do not close all vents simultaneously as this may result in the
motor/fan overheating.
The product is designed solely for cleaning air indoors and must
not be used for any other purpose.
The user is liable for damages resulting from improper use. Do
not use the air cleaner when parts or safety devices are faulty,
absent or damaged.
The air cleaner can be controlled in three different ways:
A Using the panel button (>> button), for selecting fan speed
or
AUTO mode
B Using the remote control
C Using the Auto Clean mode (
AUTO mode)
5.1 Controlling with the panel button
See fig. 2 on page 25
The panel button (>> button) allows you to control the fan
speed as follows:
With the air cleaner
OFF:
Press the panel button (>> ); control goes to AUTO.
Press the panel button (>> ); fan speed goes to •••• (TURBO).
Press the panel button (>> ); fan speed goes to ••• (
HIGH).
Press the panel button (>> ); fan speed goes to •• (MEDIUM).
Press the panel button (>> ); fan speed goes to • (
LOW).
Press the panel button (>> ); fan speed goes to STANDBY.
Press the panel button (>> ); fan speed switches OFF.
If you keep pressing on the panel button (>> ), the control will
go one step every second.
5.2 Remote Control operation
See fig. 3 on page 25
Remote Control Fan Speed Indicators:
LOW
•• MEDIUM
••• HIGH
•••• TURBO
Note: When the motor is turned ON, from STANDBY, the air
cleaner will start automatically on
TURBO for 1.5 seconds.
Subsequently it will switch to the last fan speed selected.
OFF: switches off air cleaner.
V and W : fan speed goes one level higher (V) or lower (W).
AUTO: switches the air cleaner to automatic operation.
5.3 Automatic operation (AUTO mode)
See fig. 4 on page 25
Press AUTO on the remote control.
There is a 5 minute warm up time for the Air Quality Analyzer.
It is recommended the air cleaner be plugged in continuously to
avoid the warm-up delay. If you activate
AUTO during this time,
the led on the control panel will flash. After 5 minutes you will
hear a beep and the air cleaner will operate automatically.
6 PROGRAM SETTINGS
The air cleaner is shipped with factory default program settings.
The following program settings allow you to customize the air
cleaner operation for your personal preference.
Program Setting 1: Service Indicator
Program Setting 2: Resetting the Service Indicator
PROGRAM: press this button once to get in the program mode.
While in the program mode if no key is pressed for 60 seconds
the air cleaner will return to the last setting without saving any
changes.
6.1 Program Setting 1: Service Indicator
The Service Indicator is used to predict when the filter will need
cleaning (electronic air cleaners) or replacement (media air
cleaners).
The Service Indicator automatically calculates the service
interval based on the pollution level selected and the fan speed.
When the filter becomes clogged the leds • and •••• will flash
each time the air cleaner is turned on.
Pollution level guidelines for establishing setting:
• LOW DUTY: general pollution without tobacco smoke
•• MEDIUM DUTY: moderate tobacco smoke concentrations
••• HEAVY DUTY: high tobacco smoke concentrations
•••• EXTREME DUTY: extremely high tobacco smoke
concentrations
To select the pollution level:
•Press
PROGRAM; you are in the program mode 1 and STANDBY
led will flash once every two seconds.
Default: OFF (all leds off).
•Press V: led • (
LOW) will light up, meaning you've set the
pollution level to LOW DUTY.
•Press V: led •• (MEDIUM) will light up, meaning you have set
the pollution level to MEDIUM DUTY.
•Press V: led ••• (
HIGH) will light up, meaning you have set
the pollution level to HEAVY DUTY.
•Press V: led •••• (
TURBO) will light up, meaning you have set
the pollution level to EXTREME DUTY.
If you want to go back to one of the previous pollution
levels, press W.
•Press
PROGRAM to confirm setting 1 and to go to setting 2.
6.2 Program Setting 2: Resetting the Service Indicator
The indicator needs to be reset when the media filter is changed
out. If led • and led •••• are flashing, it is time to change the
filter(s) and to reset the indicator.
To Reset:
•Press
PROGRAM: you are in the program mode 2 and the
STANDBY led will flash twice every two seconds.
Default:
OFF (all leds are off).
If the indicator is programmed (setting 1), you will see all the
leds switched on in setting 2, provided the Service Indicator
is in use for a while.
Reset Service Indicator: press
OFF (all leds are off).
•Press
PROGRAM: all user settings are saved and the air
cleaner is back in normal control.