White Rodgers 1F95-391 Heat Pump User Manual


 
The Service Button Menu allows you to view or program as many as 4 reminders that indicate when service is required.
1. Humidifiers = A programmable run time in hours to indicate on the LCD when the humidifier will need to be serviced.
2. Air Filters = A programmable run time in hours to indicate on the LCD when the filter will need to be serviced or replaced.
3. UV Lights = A programmable run time in days to indicate on the LCD when the Ultra-Violet Bulb will need to be replaced.
4. Service Timer = A programmable run time in days to indicate on the LCD when to call your service contractor.
To enter the Service Button Menu when no service reminders are on the display, press and release the SERVICE button. Press
TIME
FWD
to step through the menu items. To turn a menu item OFF or ON when selected, press or . If you are
setting an item to ON, you can then use or to select the time interval. Press
RUN
to exit the menu and return to
normal operation.
When a service reminder appears on the display, press the SERVICE button to remove it and reset the timer to begin the count
down to the next service interval.
SERVICE REMINDER
8
1
Step Press Button(s) Displayed Press or to select: COMMENTS
(Factory Default)
PAD TIME
(OFF) Hrs
or
REM PAD TIME
No. of Hrs
(ON)
or
(OFF)
Set Humidifier Maintenance Reminder.
SERVICE
3
FLTR TIME
(OFF) /Hrs
or
REM FLTR TIME
No. of Hrs
(ON)
or
(OFF)
Set Air Filter Maintenance Reminder.
TIME
FWD
Service Button Menu
Returns to Normal Operation.
PRGM
RUN
2
SET PAD TIME
(100) Hrs
25 to 1975
Selects time intervals in increments of 25 hours. The RUN
time accumulates when the HM terminal is energized.
TIME
FWD
(If PAD TIME is ON)
4 SET FLTR TIME
(200) Hrs
25 to 1975
Selects time intervals in increments of 25 hours.
The RUN time accumulates when the fan is operating.
TIME
FWD
(If FLTR TIME is ON)
5
UV TIME
(OFF) Days
or
REM UV TIME
No. of Days
(ON)
or
(OFF)
Selects UV Light Maintenance Reminder.
TIME
FWD
6
SET UV TIME
(375) Days
25 to 1975
Selects time intervals in increments of 25 days. The RUN
time is the calendar time from when it is entered or reset.
TIME
FWD
(If UV TIME is ON)
7
SERV TIME
(OFF) Days
or
REM SERV TIME
No. of Days
(ON)
or
(OFF)
Selects Routine Maintenance Service Call Reminder.
TIME
FWD
8
SET SERV TIME
(175) Days
25 to 1975
Selects time intervals in increments of 25 days. The RUN
time is the calendar time from when it is entered or reset.
TIME
FWD
(If SERV TIME is ON)