White Rodgers 1F92-71 Thermostat User Manual


 
27
Enter Cooling Program
If outside temperature is below 50°F,
we recommend that you remove the
thermostat from the wall before pro-
ceeding with the following steps to pro-
gram cooling temperatures. Personal
injury or property damage may occur
due to compressor operation in cold
weather. A fresh 9 volt Energizer
®
alka-
line battery must be installed to per-
form off-wall programming. Program-
ming away from the wall should pre-
vent accidental compressor operation.
USE
SYSTEM
SWITCH
TO TURN THERMOSTAT
OFF BEFORE REATTACHING THE
THERMOSTAT TO THE SUBBASE!
1. Press
SYSTEM
SWITCH
until COOL is displayed.
2. Follow the same procedure used to enter
your heating program, using your chosen
cooling times and temperatures.
CHECK YOUR PROGRAMMING
Follow these steps to check your thermostat
programming one final time before beginning
thermostat operation.
1. Press
SYSTEM
SWITCH
until HEAT is displayed.
2. Press and hold
VIEW
PRGM
to view the heating
period times and temperatures in sequence
for weekday, then weekend MOR, DAY,
EVE, and NHT program periods.
CAUTION
!