White Rodgers 1F85-277 Thermostat User Manual


 
CONFIGURATION MENU
Press the SYSTEM button until OFF is displayed, then press the (_ and (_ simultaneously
INSTALLER/CONFIGURATION MENU
Press Displayed Press Q or Q
Step Button(s) (Factory Default) to select Comments
1 System MS 2 SS1, HP2, HP1 Selects Single stage, Multi-stage, or Heat Pump
(Single stage or 2-stage) System Configuration
2 System 7d 5d, 0d Selects Programs Per Week
3 System PRG 4 PRG 2 Selects Programmable Periods (PRG 2 = 2
programmable periods; PRG 4 = 4 programmable periods)
4 System 4:00 HOLD 0:15 to 4:00 Selects Temporary Program Override Time
(increments of 15 minutes)
5 System EMR OFF Selects Energy Management Recovery OFF or ON
(ON)
6 System FA SL Selects Fast or Slow Cycle Selection
7 System CL CL Selects Compressor Lockout CL OFF or ON
(OFF) (ON)
8 System CDL CDL Selects Backlight Display
(ON) (OFF)
9 System FA FA Selects Fast Second Stage ON or OFF
(ON) (OFF)
10 System 0 FLTR 50-1950 (increments of 50) Selects filter replacement run time
11 System 0°F 4 LO to 4 HI Selects Temperature Display Adjustment 4 LO to 4 HI
(Room Temperature)
12 System °F °C Selects temperature display or °C selection
13 System AU On OFF Selects AUTO Mode ON or OFF
14 System LR LR 62 to LR89 Selects Limited HEAT range
(90)
15 System LR LR 46 to LR 82 Selects Limited COOL range
(45)
16 System CA CA Feature Not Available
(OFF) (ON)
17 System _ (ON) Selects Keypad Lockout
(OFF)
18 System 0 001 to 999 Selects Keypad lockout combination number
Press System to set code
19 Run Returns to the OFF position
programmable, SYSTEM button selection will skip
Programmable periods (item 3), programmable hold time
(item 4) and EMR (item 5).
3) Programmable Periods - This control can be configured
for 4 or 2 programmable periods. The display indicates
"PRG 4" in the display as default. The programmable
periods can be toggled to "PRG 2" by pressing the (E)
or (_ keys.
4) Select Temporary Program Override Time -The thermo-
stat can hold any temperature you set it to for the amount
of time you select on this option. Your choices are 0:15 to
4:00 hours in 15 minute increments.
6
Example:
1. You have selected 3:00 hours for the Temporary Pro-
gram Override time period.
2. With the thermostat set to Heat or Cool, press (_ or C)
to set the temperature to your preference.
The thermostat will maintain this temperature setting for
3 hours with "HOLD" blinking to remind you it is in
Temporary Hold. After 3 hours, the thermostat will go
back to the program temperature and "HOLD" will no
longer blink or display.