4
INSTALLER/CONFIGURATION MENU
Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the
next menu item. Press
or to change a menu item. Shaded items are not available on 1F86.
1. Select Reversing Valve Output (SS/HP switch must
be set at HP, omitted if SS/HP switch is SS Position)
– The O/B option is factory set at "O" position. This will
accommodate the majority of heat pump applications,
which require the changeover relay to be energized in
FRIO. If the thermostat you are replacing or the heat pump
being installed with this thermostat requires a "B" terminal,
to energize the changeover relay in CALOR, the O/B
option should be set at "B" position.
2. Program Options 1F80 only – This control can be
confi gured for 5/2 day or 5/1/1 day programming or non-
programming mode. The default setting is P2, indicating
5/2 day programming. The programs per week can be
toggled to P3 or P0 by pressing the
or keys. A
selection of 0 Days for non-programmable will eliminate
the need for EMR, and that step in the menu will be
skipped.
3. Select Frio Ahorro (Cool Savings™) and value
– Selects the Frio Ahorro feature On or OFF. If selected
On, press MENU to select the amount of adjustment
for the feature in Frio mode with 1 (1°) being the least
amount of adjustment and 6 (6°) being the most amount
of adjustment. Default value is 3 (3°). In normal operation
"Ahorro" will appear under "Vent"
Cool Savings is an optional energy saving feature that
can reduce your cooling costs. It is based on the principal
that lower indoor humidity makes a slightly higher
temperature feel more comfortable. Frio Ahorro operates
during periods of high demand which normally occur
on the hottest summer days when the cooling system
may run for hours to reach the thermostat setting. Long
cooling run times also lower the indoor humidity. Frio
Ahorro very slowly adjusts the setpoint temperature to
make the setpoint closer to the displayed temperature, to
a maximum number of degrees selected. Adjusting the
setpoint temperature over a long cooling run time allows
the system to reach your set temperature and turn off.
The room temperature will actually be higher than the
thermostat displays, but the reduction in humidity will allow
comfort at the slightly higher temperature. When Frio
Ahorro is making adjustments, "Save" will show next to
the setpoint temperature and the room temperature may
vary within the adjustment range selected.
If this feature is selected OFF, no change will occur when
the cooling system is continually running during periods of
high demand.
INSTALLER/CONFIGURATION MENU
MENU
REF HP SS
PRESS
BUTTON
DISPLAYED
(FACTORY DEFAULT)
Press or to
select from listed options
COMMENTS
1 1 MENU
On (Frio O) Calor b On
Reversing Valve Output (SS/HP switch must
be in the Heat Pump HP position)
2 2 1 MENU
P (2) P 3, P 0
Selectable Programs Per Week
(For programmable thermostat only)
3 3 2 MENU
Frio Ahorra CE
(OFF)
Frio Ahorra CE On Select Frio Ahorra (Cool Savings) on or off
MENU
Frio Ahorra (3) 6, 5, 4, 2, 1 Selects Frio Ahorra value 1 (low) to 6 (high)
4 4 3 MENU
E (On) E OFF Selects Energy Management Recovery (EMR)
on or off
5 4 MENU
CR Calor
(ME)
AL, bA Adjustable Anticipation (Calor) (only when
SS/HP switch is at the SS position)
6 5 MENU
CR Frio
(AL)
bA Adjustable Anticipation (Frio) (only when
SS/HP switch is at the SS position)
7 5 MENU
CR Bomba de Calor
(AL)
bA Adjustable Anticipation (Bomba de Calor)
(only when SS/HP switch is at the HP position)
8 6 6 MENU
Cd (OFF) Cd On Compressor Lockout Time
9 7 7 MENU
Auto Calor
Frio Off
Calor Frio Off,
Calor Off with Vent icon,
Calor Off without Vent
icon, Frio Off,
Auto Off
System Mode Confi guration
with Automatic Changeover
10 8 8 MENU
L (On) L OFF Selects Display Light on or off
11 9 9 MENU
0 1 AL, 2 AL, 3 AL, 4
AL,
1 bA, 2 bA, 3 bA, 4 bA
Adjustable Ambient Temperature Display
12 10 10 MENU
F C Selects Fahrenheit/Celsius Temperature
Display
13 11 11 MENU
Cambiar Filtro (OFF) Cambiar Filtro On Selects Filter Change-out Indicator
MENU
Cambiar Filtro 200 h 25 h to 1975 h in
25-hour increment
When on, selects time in 25 hour increments
14 12 12 Arrancar
Returns to Normal Operation