Whirlpool CAW21D2A1 Air Conditioner User Manual


 
RECOMMENDED GROUNDING METHOD
Chart-D
For your personal safety, this appliance must be
grounded. This appliance is equipped with a
power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding type wall receptacle, grounded in
accordance with the National Electrical Code
and local codes and ordinances. If a mating wall
receptacle is not available, it is the personal
responsibility and obligation of the customer to
have a properly grounded 3-prong wall receptacle
installed by a qualified electrician.
ELECTRICAL
REQUIREMENTS
For 230 volt and 230/208 volt models with
serial plate amperes up through 24.0
Refer to Chart D for specific wiring and
receptacle information to be used.
OBSERVE ALL LOCAL GOVERNING CODES
AND ORDINANCES.
Do not, under any circumstances, remove the
power supply cord ground plug.
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE.
A three-wire, single-phase 60 hertz AC only
electrical supply is required.
A separate electrical supply is required on a
separately fused circuit. Do not fuse ground-
neutral.
See Chart D for receptacle voltage require-
ments, proper fuse size, wire and wiring
connections which must conform with rating of
the appliance. Do not use an extension cord.
PLUG AND
RECEPTACLE
DATA
RECEPTACLE
VOLTAGE
(60 HERTZ
AC IN ALL
INSTANCES)
SERIAL PLATE
AMPERES
RECEPTACLE _
MODEL WITH
SERIAL PLATE
OF 230 VOLTS
(207 MIN,253
MAX.)
“P
through
1
MODEL WITH
24.0
SERIAL PLATE
OF 2301209
VOLTS
(197.6 MIN-
253 MAX.)
USE TIME-DELAY
FUSE
OR TIME
DELAY CIRCUIT
BREAKER
RATING IN
AMPS
MINIMUM
RECEPTACLE
WIRE SIZE
SEE BELOW
TYPE
OF BRANCH
CIRCUIT
CART.
TYPE
ONLY
10 GAUGE
USE COPPER
WIRE ONLY
SINGLE
OUTLET
ONLY
RECEPTACLE WIRING
RECEPTACLE WIRING should be at least as
large as size shown on electrical Chart D. Use
copper wire only. It is the personal responsibility
and obligation of the customer to provide
proper and adequate receptacle wiring installed
by a qualified electrician.OBSERVE NATIONAL
ELECTRICAL CODE A:\ID ALL LOCAL
GOVERNING CODES AND ORDINANCES.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be
grounded. This appliance is equipped with a
power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3-prong
grounding type wall receptacle, grounded in
accordance with the National Electrical Code
and local codes and ordinances. If a mating wall
receptacle is not available, it is the personal
responsibility and obligation of the customer to
have a properly grounded 3-prong wall receptacle
installed by a qualified electrician.