Whirlpool AD0402XS0 Dehumidifier User Manual


 
1.
To remove outer cabinet,
o Disconnect power cord.
D Take off the plastic grille. Remove the two
screws at the bottom. Drop grille down ana
take out
TOP FLANGE
SCREWS
(side of cabinet)
c. Remove the socket head screws on each side
and top flange screws (see illustrations). On 30,
40 and 48 pt. models, also remove rear grille.
Pull out at bottom and drop grille down.
d Lift cabinet from unit.
2. Coils should be inspected annually. If needed.
brush clean with warm water and mild de-
tergent. Rinse and dry. Be sure power supply
cord is disconnected.
COILS
3. The compressor IS sealed and needs no oiling
4. The fan motor is prelubricated and does not
require further oiling under normal operating
conditions. However, if the dehumidifier is oper-
ated under severe environmental conditions
(dust, dirt, high temperatures) the fan motor
should be oiled annually through the provided
oil tubes (holes]. An easy to use capsule of es-
pecially recommended oil (Part Number 10943)
IS available through your nearest Whirlpool
Factory Service Center, or use SAE #20 non-
detergent oil.
5. Wash plastic parts with a soft cloth, warm water
and mild detergent. Rinse and dry with a soft
cloth.
6. Replace cabinet grille(s). Reconnect power