Whirlpool BFG1H5040T3NOV 5K Water Heater User Manual


 
22
Replacing the Thermocouple
1. Remove the manifold assembly as directed previously.
2. Remove the retainer clip from the back of the two piece
wire connector and remove the two piece wire connec-
tor from the manifold door (Figure 25).
3. Pull the thermocouple from the pilot assembly (Figure
29).
IMPORTANT: Be careful not to bend or alter the position of
the pilot assembly components.
4. Push the new thermocouple through the holes in the pi-
lot bracket. Insert the thermocouple tube into the holes
provided in the pilot assembly until it clicks into place.
5. Position the new thermocouple through the larger
opening of the two piece wire connector (Figure 25). Be
sure igniter wire is positioned through the small open-
ing of the two piece wire connector.
6. See Replacing the Manifold Assembly.
Figure 25
Two Piece Wire
Connector
Assembly
Two Piece
Wire Connector
Thermocouple
Retainer Clip
Manifold
Door
Other fittings
not shown
for clarity
Pilot Tube
Igniter Wire
Figure 26
Thermocouple
Assembly
Mirror
Mirror
Flashlight
Figure 27
Flame-trap visual inspection
External Inspection & Cleaning of the
Flame-trap
Although not likely to occur, if debris collects on the flame-
trap, use a vacuum, compressed air, or a soft bristle brush
to remove it. NOTE: If unable to inspect or clean the flame
trap from underneath, follow the “Cleaning the Combustion
Chamber and Flame-trap” instructions.
Cleaning the Combustion Chamber and
Flame-trap
1. Follow procedure outlined in “Removing the Manifold
Assembly”.
2. Use a vacuum cleaner/shop vac to remove all loose
debris in the combustion chamber (Figure 28A). Use
compressed air to clear any dust or debris that may
have accumulated in the flame-trap.
3. Reassemble following the procedure under “Replacing
the Manifold Assembly”.