Whirlpool AKM Stove User Manual


 
SERVICE
22.11.1999 / Page 2 AKM 460/NB/01 Whirlpool Europe
Doc. No: 4812 725 11766 8571 460 38020 Customer Service
Technical data
Type of gas
used
Type of
burner
Injector
marking
Rated heat
capacity
(PCS-kW)
Rated
consumption
Reducedheat
capacity
(PCS-kW)
Gas pressure
(mbar)
min. rat. max.
Natural Gas
(Methane)
G 20
large
medium
small
128
94
76
3.00
1.65
1. 0 0
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
17 20 25
LPG
(Cylinder)
G 30
large
medium
small
85
65
50
3.00
1.65
1. 0 0
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
20 28-30 35
LPG
(Cylinder)
G 31
large
medium
small
85
65
50
3.00
1.65
1. 0 0
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
25 37 45
City Gas
G 110
large
medium
small
270
185
145
3.00
1.65
1. 0 0
680 l/h
374 l/h
227 l/h
0.60
0.35
0.30
6815
Type of gas used Appliance
model
Total rated heat
capacity
(PCS-kW)
Total rated
consumption
Air required for
burning (m/h)
G20 20 mbar 5 gas 10.30 999 l/h 20.6
G30 28-30 mbar 5 gas 10.30 749 g/h 20.6
G31 37 mbar 5 gas 10.30 735 g/h 20.6
G110 8 mbar 5 gas 10.30 2335 l/h 20.6
1. Medium burner
2. Medium burner
3. Large burner
4. Small burner
5. Large burner
Voltage: 230 V
Frequency: 50 Hz